Notes:
53 = Split System
42 = Indoor Unit
38 = Outdoor Unit
Q = Heat Pump
K = Cool Only
H = Hi Wall System
E = Elite Series
T = High Ambient
30 = System Size
7 = Nominal Power Supply 220-240V~ 50Hz 1Ph
0 = Wireless Remote Control
8 = Miraco – Carrier
F = Ionizer Function
5. OPERATING LIMITS *
COOLING
HEATING *
Difference
Dry Bulb
Temp. C°
Wet Bulb
Temp. C°
Difference
Dry Bulb
Temp. C°
Wet Bulb
Temp. C°
Indoor temperature
Maximum
Minimum
32
21
23
15
Indoor temperature
Maximum
Minimum
27
20
-
Outdoor temperature
Maximum
Minimum
*
21
Outdoor temperature
Maximum
Minimum
24
2
18
1
MAIN POWER SUPPLY
Nominal
220-240V~ 50Hz 1Ph
Min. Voltage 198
Max. Voltage 254
NOTES:
** 52°C for models 53KHET30-708F & 53KHET36-708F & 53QHET30-708F & 53QHET36-708F
46°C for model 53QHE30-708F
** When the system operates above or below these limits for a long time, system diagnostics
may detect a malfunction and the system will not operate properly.
*** During heat pump operation, the system will undergo several defrost cycles to eliminate ice
that might possibly collect on the outdoor unit in very low ambient temperatures.
After completions of defrost cycle, the system will normally operate