HEATING
&
COOLING
58ED,PB
Horizontal
Gas-Fired
Furnaces
Use
only
copper
wire
for
115
v
supply
service
to
furnace.
When
replacing
any
original
wiring,
use
only
105
C,
16
gage
AWG
copper
wire.
Instructions
for
wiring
the
thermostat
are
packaged
with
the
thermostat
(field
supplied).
Make
connections
as
shown
in
wiring
labels
at
the
24
v
terminal
board
located
on
the
electrical
junction
box.
When
installing
accessories
to
this
furnace,
follow
manufacturer’s
instructions
included
with
the
accessory
Except
for
thermostat
wiring,
a
minimum
of
typeT
(63
F
rise)
must
be
used.
Step
8
Install
Filters
Filters
and
racks
are
available
as
accessories.
See
Fig.
8
for
recommended
filter
size
rating
and
type.
IMPORTANT:
All
furnaces
must
be
equipped
with
a
filter.
Step
9
Reverse
Components
(if
required).
A
WARNING
Before
proceeding
with
component
reversal,
make
sure
that
all
power
is
turned
off
upstream
of
furnace
and
all
gas
piping
is
shut
off
and
disconnected
from
furnace.
A
CAUTION
Before
proceeding
with
field
reversing,
ensure
a
correct
wiring
diagram
is
available
and/or
be
prepared
to
mark
all
wiring
as
it
is
disconnected.
INPUT
A
(1000
BTUH)
(IN)
50
144
75
100
161
125
20
4
140
CJl
C*»
NOTE:
FILTER
RACK
TO
INLET
END
OF
FURNACE
INSTALLED
INTO
RETURN
DUCTWORK.
Fig.
8
Accessory
Filter
Rack
Assembly
All
references
to
left
or
right
side
of
furnace
refer
to
the
furnace
looking
at
the
heat
exchanger
(supply
air
side).
The
gas
valve,
pilot
burner
components
and
controls
may
be
reversed
as
follows:
1
Loosen
burner
removal
cover
screws
and
remove
both
covers
2
Disconnect
all
wires
to
gas
valve
and
unplug
the
igniter
cable
from
the
ignition
control
(if
so
equipped).
3.
Remove
the
manifold
locking
device
and
slide
the
burner
and
manifold
assembly
back
towards
the
furnace
inlet
until
the
burners
are
clear
of
the
heat
exchanger
tubes.
See
Fig.
5.
4.
Slide
manifold
assembly
towards
the
front
of
furnace
.
until
it
clears
the
blower
deck.
NOTE:
Keep
manifold
assembly
straight
while
removing.
If
manifold
is
cocked,
then
the
assembly
will
bind
in
burner
box.
5.
Place
manifold
on
a
work
area
and
disconnect
the
pilot
tubing
and
thermocouple,
if
equipped,
from
the
valve
6.
Using
2
pipe
wrenches
(one
on
the
gas
valve
and
one
on
the
manifold
extension
pipe),
remove
the
gas
valve
7.
Remove
the
manifold
extension
pipe
from
the
manifold
(it
may
be
necessary
to
put
a
pipe
wrench
on
the
manifold
pipe
while
turning
the
extension).
8.
Using
2
pipe
wrenches
(one
on
the
manifold
pipe
between
the
pipe
cap
and
burner
orifices
and
one
on
the
pipe
cap),
remove
the
pipe
cap.
9.
Clean
the
threads
on
manifold
pipes,
gas
valve
and
pipe
cap
of
any
old
pipe
dope.
NOTE:
Use
a
joint
compound
(pipe
dope)
resistant
to
the
action
of
liquefied
petroleum
gases
or
to
any
other
chemical
constituents
of
the
gases
to
be
conducted
through
the
piping.
10.
Using
a
suitable
joint
compound
and
2
pipe
wrenches,
replace
the
manifold
pipe
extension
where
the
pipe
cap
was.
The
pipe
extension
should
be
tightened
and
positioned
so
that
it
is
pointing
towards
the
back
of
the
burners.
11.
Using
2
pipe
wrenches
(one
on
the
manifold
exten¬
sion
and
the
other
on
the
gas
valve),
tighten
gas
valve
to
the
extension
and
position
the
valve
so
that
the
manual
knob
is
in
the
12
o’clock
position
12.
Using
2
pipe
wrenches
(one
on
the
pipe
cap
and
the
other
on
the
manifold
pipe),
tighten
the
pipe
cap
to
the
other
end
of
the
manifold
pipe
13.
Remove
the
screws
holding
the
pilot
bracket
to
the
crossovers
of
the
first
2
burners
When
removing
pilot
assembly,
be
careful
not
to
damage
the
pilot
gas
tubing
and
ignition
cable
(or
thermocouple,
if
so
equipped).
NOTE
This
step
is
not
required
foi
050
size,
as
there
are
only
2
burners
Manufacturer
reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and
without
incurring
obligations.
Book
I
I
1
4
PC
101
Catalog
No
535-834
Printed
in
U
S
A
Form
58ED.PB-1SI
Pgll
6-85
Replaces:
58PB-1SI
Tab
16a
1
8
a
For
replacement
items
use
Carrier
Specilied
Parts

Related product manuals