HEATING
&
COOLING
58ED,PB
Horizontal
Gas-Fired
Furnaces
LOCATION
OF
SHUTTER
LOCKING
SCREW
SHUTTER
ADJUSTING
TAB
NOTE:
LOOSEN
LOCKING
SCREW
BEFORE
ADJUSTING
SHUTTER.
RETIGHTEN
SCREW
AFTER
FINAL
ADJUSTMENTS
ARE
MADE.
Fig.
14
Air
Shutter
Adjustment
Manifold
Pressure
Adjustment
For
natural
gas,
best
results
are
obtained
with
a
manifold
pressure
of
3.0
in.
to
3.5
in.
wg.
Remove
pressure
tap
pipe
plug
from
the
gas
valve
and
connect
to
a
water
manometer.
Measure
gas
pressure
with
the
furnace
on.
Turn
regulator
adjusting
screw
in
to
increase
pressure,
or
out
to
decrease
pressure.
For
LP
gases,
a
10
in.
wg
pressure
is
required.
Input
rate
must
be
maintained
at
±
2%.
Fan
Adjustment
Check
This
furnace
is
equipped
with
a
3-speed
direct
drive
motor
to
deliver
a
temperature
rise
within
the
range
specified
on
the
rating
plate,
between
the
return
and
supply
plenums
at
the
external
duct
static
pressure
noted
on
the
AGA
rating
plate.
Consult
the
wiring
diagram
for
speed
changes
on
the
direct
drive
motor.
Adjust
fan
speed
so
that
temperature
rise
is
within
rating
plate
specifications.
Fan
and
Limit
Control
Check
After
the
furnace
has
been
operating
for
at
least
15
minutes,
restrict
the
return
air
supply
by
blocking
the
filters
or
closing
the
return
air
registers
and
allow
the
furnace
to
shut
down
on
high
limit.
The
fan
must
continue
to
run.
Remove
the
restriction
and
the
burner
should
come
on
in
a
few
minutes.
The
operational
checkout
is
now
complete.
Be
sure
to
adjust
the
thermostat
to
the
desired
setting
and
inform
the
owner
how
to
operate
the
furnace
system
before
leaving
the
jobsite.
Stopping
the
Furnace
Follow
these
procedures
to
shut
down
the
furnace
for
the
summer,
if
required.
1.
Disconnect
electrical
power
to
all
accessories.
2.
To
shut
down
main
burner,
turn
gas
cock
dial
clock¬
wise
to
OFF
position
3.
(Standing
pilot
models
only):
To
shut
down
both
pilot
and
main
burner,
depress
dial
and
turn
clockwise
to
OFF
position
4.
Turn
off
all
electrical
power
to
furnace.
5.
Turn
off
water
supply
to
humidifier,
if
so
equipped.
SERVICE
AND
MAINTENANCE
A
CAUTION
The
ability
to
properly
perform
maintenance
on
this
equipment
requires
certain
mechanical
skills
and
tools.
If
you
are
at
all
uncertain,
contact
your
Carrier
dealer
for
qualified
maintenance
and
service.
A
WARNING
Turn
off
all
gas
and
electrical
power
to
furnace
before
performing
any
maintenance
or
service
on
unit.
Failure
to
take
this
precaution
may
result
in
personal
injury
due
to
electrical
shock
or
uncon¬
trolled
gas
leakage.
NOTE:
Furnace
is
equipped
with
a
blower
door
switch
which
cuts
electric
power
when
blower
door
is
removed.
Air
Filter
In
order
to
acquaint
the
user
of
the
furnace
with
proper
procedure
for
inspecting
and
cleaning
the
filter,
the
installer
should
instruct
the
user
to
locate,
remove,
clean
and
replace
the
furnace
filter(s).
NOTE:
If
furnace
is
equipped
with
accessory
filter
rack,
refer
to
section
on
page
11.
A
CAUTION
Personal
injury
or
property
damage
may
result
if
furnace
is
operated
with
the
blower
compartment
door
removed.
A
lack
of
adequate
combustion
air
may
cause
the
main
burner
flame
to
be
drawn
out
of
the
furnace
unless
blower
compartment
door
is
secured.
After
inspecting
or
replacing
the
filter,
be
sure
that
the
blower
compartment
door
is
securely
fastened
in
place.
Never
operate
the
furnace
without
a
filter.
Lubricating
Motors
Direct
drive
motor
and
blower
assemblies
are
factory
lubricated
and
normally
do
not
require
oiling.
Manufacturer
reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and