HEATING
A
COOLING
58ED,PB
Horizontal
Gas-Fired
Furnaces
Cleaning
Heat
Exchanger
and
Venting
System
The
heat
exchanger
and
venting
system
should
be
checked
each
year
by
a
qualified
dealer.
If
necessary,
the
following
procedures
should
be
performed:
1.
Make
sure
that
all
utilities
are
turned
off
upstream
of
the
furnace
(both
gas
and
electrical
supplies).
2.
Remove
burner
covers,
manifold
assembly
with
burners,
vent
connectors
and
draft
hood.
3.
Clean
flue
box,
flue
ways,
burner
box
and
burners
with
brush
and/or
vacuum
cleaner.
4.
After
cleaning,
check
pilot
for
proper
position.
Replace
all
parts.
5.
T
urn
on
gas
and
electrical
supplies.
Test
for
leaks
using
soap
and
water
solution.
A
CAUTION
Never
use
an
open
flame
when
testing
for
gas
leaks.
Use
a
soap
and
water
solution.
6.
C
h
eck
for
proper
operation
of
all
controls.
Table
7
Trouble
Analysis
Chart
for
Standing
Pilot
Models
A
WARNING
Turn
off
gas
and
electrical
supplies
to
furnace
before
servicing.
(Unless
specific
test
requires
gas
and
electrical
supplies
)
SYMPTOM
AND
PROBABLE
CAUSE
REMEDY
BURNERS
WILL
NOT
IGNITE
1
Pilot
light
out
1
Relight
pilot
If
pilot
does
not
remain
lit,
replace
thermocouple
2
No
115-v
power
to
furnace
j
2.
Connect
to
power
supply.
Check
fuse,
wiring
or
circuit
breaker.
3
No
24-v
power
to
control
circuit
3.
Check
transformer;
replace.
4.
Miswired
or
loose
connections
4
Check
all
wiring
and
wirenut
connections.
5.
No
gas
at
main
burners
5
Check
to
see
if
main
valve
is
operating
Look
for
loose
or
broken
wiring
connections
If
no
deficiency
is
found,
replace
valve
assembly.
6
Flame
probe
or
connecting
lead
is
shorted
or
open
6.
Correct
electrical
shorting
or
open
circuit
INADEQUATE
HEATING
1
Furnace
undersized
for
application
1
Replace
with
proper
size
furnace
2
Gas
input
to
furnace
too
low
2.
Check
gas
pressure
at
manifold.
Clock
gas
meter
for
input
If
too
low,
increase
manifold
pressure,
or
replace
with
correct
orifices.
3
Limit
switch
cycles
main
burners
3
OFF
setting
of
fan
control
set
too
high;
reset.
Dirty
air
filters;
clean
and
reinstall.
Blower
speed
too
low;
use
faster
speed
tap
Registers
closed,
restricted
ductwork,
open
or
remove
restriction
Check
heat
anticipator
setting
on
thermostat,
readjust.
ALDEHYDE
ODORS
(CO),
SOOTING
FLAME,
FLOATING
FLAME
1
Incomplete
combustion
poor
flame
characteristics
1
Air
shutter
on
burners
closed,
adjust
to
soft,
blue
flame.
Check
all
screws
aroundflueoutletsand
burner
compartment,
tighten
Lack
of
combustion
air,
see
Installation
section
Cracked
heat
exchanger;
replace
Overfired
furnace;
reduce
input
or
change
orifices.
Check
vent
for
restriction;
clean
as
required
Manufacturer
reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and
without
incurring
obligations.
BookII
1
4
PC101
Catalog
No
535-834
Printed
in
U
S
A
Form58ED,PB-1SI
Pg
16
6-85
Replaces:
58PB-1SI
Tab
16a
18a
For
replacement
items
use
Carrier
Specified
Parts.