HEATING
&
COOLING
58ED,PB
Horizontal
Gas-Fired
Furnaces
Table
8
Trouble
Analysis
Chart
for
Electronic
Ignition
Models
SYMPTOM
AND
PROBABLE
CAUSE
REMEDY
PILOT
WILL
NOT
LIGHT
1
No
spark
at
electrode
1
Check
spark
gap,
refer
to
Start-Up
and
Adjustment
section
Check
if
induced
draft
motor
is
operating
If
not,
check
power
to
motor
Check
for
any
blockage
in
flue
venting
system
and
chimney,
thereby
preventing
pressure
switch
from
closing
Unblock
if
necessary
Check
moisture
or
dirt
accumulation
on
electrode
ceramic,
clean
ceramic
with
cloth
Cracked
ceramic,
replace
pilot
electrode
assembly
Check
for
loose
or
broken
wiring
at
and
between
electronic
control
box
and
electrode.
Replace
wire
as
necessary
Check
fuse
or
circuit
breaker
for
115-v
supply
to
furnace
Check
24
v
input
to
electronic
control
box
If
you
read
24
v,
and
above
steps
have
been
completed,
replace
electronic
control
box
assembly
Check
pressure
switch
and
tube
assembly
for
any
blockage
that
prevents
pressure
switch
from
operating
Check
continuity
to
determine
if
pressure
switch
has
disengaged
2
Spark
shorting
out
to
main
burner
2
Realign
electrode
tip
away
from
main
burner
but
maintain
spark
gap
to
pilot
burner
as
noted
above
3.
No
gas
at
pilot
burner
3
Check
to
see
if
pilot
valve
is
opening
Look
for
loose
or
broken
wiring
connections
If
no
deficiency
is
found,
replace
valve
assembly
BURNERS
WILL
NOT
IGNITE
1
No
115-v
power
to
furnace
1
Connect
to
power
supply
Check
fuse,
wiring
or
circuit
breaker
2.
No
24-v
power
to
control
circuit
2
Check
transformer;
replace
3.
Miswired
or
loose
connections
3
Check
all
wiring
and
wirenut
connections
4
No
gas
at
main
burners
4
Check
to
see
if
main
valve
is
operating.
Look
for
loose
or
broken
wiring
connections
If
no
deficiency
is
found,
replace
valve
assembly
5
Flame
probe
or
connecting
lead
is
shorted
or
open
5.
Correct
electrical
shorting
or
open
circuit
INADEQUATE
HEATING
1.
Furnace
undersized
for
application
1
Replace
with
proper
size
furnace
2
Gas
input
to
furnace
too
low
2
Check
gas
pressure
at
manifold
Clock
gas
meter
for
input.
If
too
low,
increase
manifold
pressure,
or
replace
with
correct
orifices
3
Limit
switch
cycles
main
burners
3
OFF
setting
of
fan
control
set
too
high,
reset
Dirty
air
filters,
clean
and
reinstall.
Blower
speed
too
low,
use
faster
speed
tap
Registers
closed,
restricted
ductwork,
open
or
remove
restriction.
Check
heat
anticipator
setting
on
thermostat;
readjust
ALDEHYDE
ODORS
(CO),
SOOTING
FLAME,
FLOATING
FLAME
1
Incomplete
combustion
poor
flame
characteristics
1
Air
shutter
on
burners
closed,
adjust
to
soft,
blue
flame
Check
all
screws
around
flue
outlets
and
burner
compart¬
ment;
tighten
Lack
of
combustion
air,
see
Installation
section
Cracked
heat
exchanger,
replace
Overfired
furnace;
reduce
input
or
change
orifices
Check
vent
for
restriction;
clean
as
required
Manufacturer
reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and
without
incurring
obligations.
Bookll
14
PC101
Catalog
No
535-834
PrintedinUSA
Form
58ED,PB-1SI
Pg
17
6-85
Replaces:
58PB-1
SI
Doric