EasyManua.ls Logo

Carrier 59MN7A - Safety Considerations

Carrier 59MN7A
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
SPECIFICATIONS
Heating Capacity and Efficiency 060-14 060-20 080-14 080-20 100-22 120-22
Input Maximum Heat (BTUH) 60,000 60,600 80,000 80,000 100,000 120,000
Intermediate Heat (BTUH) 39,000 39,000 52,000 52,000 65,000 78,000
Minimum Heat (BTUH) 24,000 24,000 32,000 32,000 40,000 48,000
Output Maximum Heat (BTUH) 59,000 60,000 78,000 78,000 98,000 117,000
Intermediate Heat (BTUH) 38,000 39,000 51,000 51,000 64,000 76,000
Minimum Heat (BTUH) 24,000 24,000 31,000 31,000 39,000 47,000
Efficiency AFUE % (ICS) 97.4 98.5 97.4 97.2 97.3 97.2
Certified Temperature
Rise Range ºF C)
Maximum Heat
35 - 65
(19 - 36)
35 - 65
(19 - 36)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
45 - 75
(25 - 42)
45 - 75
(25 - 42)
Intermediate Heat
50 - 80
(28 - 44)
40 - 70
(22 - 39)
50 - 80
(28 - 44)
50 - 80
(28 - 44)
50 - 80
(28 - 44)
50 - 80
(28 - 44)
Minimum Heat
35 - 65
(19 - 36)
25 - 55
(14-31)
35 - 65
(19 - 36)
35 - 65
(19 - 36)
35 - 65
(19 - 36)
35 - 65
(19 - 36)
Airflow Capacity and Blower Data 060-14 060-20 080-14 080-20 100-22 120-22
Rated External Static
Pressure (in. w.c.)
Heating 0.12 0.12 0.15 0.15 0.20 0.20
Cooling 0.5 0.5 0.5 0.5 0.5 0.5
Airflow Delivery
@ Rated ESP (CFM)
Maximum Heat 1075 1080 1500 1345 1575 1820
Intermediate Heat 530 690 750 795 955 1100
Minimum Heat 415 555 620 595 745 900
Cooling 1335 1905 1375 1945 2160 2185
Cooling Capacity (tons)
400 CFM/ton 3 4.5 3.5 4.5 5.5 5.5
350 CFM/ton 3.5 5.5 4 5.5 6 6
Direct-Drive Motor Type Electronically Commutated Motor (ECM)
Direct-Drive Motor HP 1/2 1 1/2 1 1 1
Motor Full Load Amps 7.7 12.8 7.7 12.8 12.8 12.8
RPM Range 300 - 1300
Speed Selections Variable (Communicating)
Blower Wheel Dia x Width in. 11 x 8 11 x 10 11 x 8 11 x 10 11 x 10 11 x 11
Air Filtration System
Factory Supplied Media Cabinet
Field Supplied Filter
Filter Used for Certified Watt Data* KGAWF**06UFR
Electrical Data 060-14 060-20 080-14 080-20 100-22 120-22
Input Voltage Volts-Hertz-Phase 115-60-1
Operating Voltage Range Min-Max 104 -127
Maximum Input Amps Amps 9.7 14.8 9.7 14.8 14.8 14.8
Unit Ampacity Amps 12.7 19.1 12.7 19.1 19.1 19.1
Minimum Wire Size AWG 14 12 14 12 12 12
Maximum Wire Length
@ Minimum Wire Size
Feet 29 30 29 30 30 30
(M) (8.8) (9.1) (8.8) (9.1) (9.1) (9.1)
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Amps 15 20 15 20 20 20
Transformer Capacity (24vac output) 40 VA
External Control Power
Available
Heating 27.9 VA
Cooling 34.6 VA
Controls 060-14 060-20 080-14 080-20 100-22 120-22
Gas Connection Size 1/2" - NPT
Burners (Monoport) 3 3 4 4 5 6
Gas Valve (Redundant) Manufacturer White Rogers
Minimum Inlet Gas pressure (in. wc) 4.5
Maximum Inlet Gas pressure (in. wc) 13.6
Gas Conversion Kit - Natural to Propane KGANP5201VSP
Gas Conversion Kit - Propane to Natural KGAPN4401VSP
Manufactured (Mobile) Home Kit not approved for MH use
Ignition Device Silicon Nitride
* See Accessory List for part numbers available.
59MN7A

Other manuals for Carrier 59MN7A

Related product manuals