Check
Safety
Controls
The
flame
sensor,
gas
valve,
and
pressure
switch
were
all
checked
in
the
Start-up
procedure
section
as
part
of
normal
operation.
1.
Check
Main
Limit
Switch
This
control
shuts
off
combustion
system
and
energizes
air-
circulating
blower
motor,
if
furnace
overheats.
By
using
this
method
to
check
the
temperature
limit
control,
it
can
be
es-
tablished
that
the
limit
is
functioning
properly
and
that
the
limit
will
operate
if
there
is
a
restricted
return-air
supply
or
motor
failure.
If
the
limit
control
does
not
function
during
this
test,
the
cause
must
be
determined
and
corrected.
a.
Run
furnace
for
at
least
5
minutes.
b.
Gradually
block
off
return
air
with
a
piece
of
cardboard
or
sheet
metal
until
the
limit
trips.
c.
Unblock
return
air
to
permit
normal
circulation.
d.
Burners
will
re-light
when
furnace
cools
down.
.
Check
Pressure
Switch(es)
This
control
proves
operation
of
the
draft
inducer
blower.
bo
a.
Turn
off
115-v
power
to
furnace.
b.
Disconnect
inducer
motor
lead
wires
from
wire
harness.
c.
Turn
on
115-v
power
to
furnace.
d.
Set
thermostat
to
“call
for
heat”
and
wait
1
minute.
When
pressure
switch
is
functioning
properly,
hot
surface
igniter
should
NOT
glow
and
control
diagnostic
light
flashes
a
status
code
31.
If
hot
surface
igniter
glows
when
inducer
motor
is
disconnected,
shut
down
furnace
immediately.
e.
Determine
reason
low
pressure
switch
did not
function
properly
and
correct
condition.
f.
Turn
off
115-v
power
to
furnace.
g.
Reconnect
inducer
motor
wires,
replace
outer
door,
and
turn
on
115-v
power.
h.
Blower
will
run
for
90
sec
before
beginning
the
call
for
heat
again.
i.
Furnace
should
ignite
normally.
Checklist
1.
Put
away
tools
and
instruments.
Clean
up
debris.
2.
Verify
that
the
jumper
is
removed
from
the
TEST/TWIN
terminal.
Verify
that
there
is
nothing
plugged
into
the
PLT
connector.
(Note:
If
there
is
a
jumper
connector
plugged
into
PLT,
remove
it
and
discard.) See
Fig.
36.
3.
Verify
that
the
Blower/Heat
Off
Delay
jumpers
are
set
as
desired.
See
Fig.
36
and
65.
4.
Verify
that
the
blower
(lower
door
in
upflow
position)
and
control
(“Main”
or
upper
door
in
upflow
position)
doors
are
properly
installed.
5.
Verify
that
the
Status
LED
glows.
If
not,
check
that
the
power
supply
is
energized
and
that
the
blower
door
is
secure,
See
Fig.
56
to
interpret
diagnostic
codes.
6.
Cycle
test
furnace
with
room
thermostat
to
be
sure
that
it
operates
properly
with
the
room
thermostat.
Check
all
modes
including
Heat,
Cool
and
Fan.
7.
Check
operation
of
accessories
per
manufacturer’s
instructions.
8.
Review
Owner’s
Manual
with
owner.
9,
Attach
entire
literature
packet
to
furnace.
Table
19
Altitude
Derate
Multiplier
for
U.S.A.
ALTITUDE
PERCENT
DERATE
OF
MULTIPLIER
FT.
M
DERATE
FACTOR*
0-2000
0-610
0
1.00
2001-3000
610-914
4-6
0.95
3001-4000
914-1219
6-8
0.93
4001-5000
1219-1524
8-10
0.91
5001-6000
1524-1829
10-12
0.89
6001-7000
1829-2134
12-14
0.87
7001-8000
2134-2438
14-16
0.85
8001-9000
2438-2743
16-18
0.83
9001-10,000
2743-3048
18-20
0.81
*Derate
multiplier
factors
are
based
on
midpoint
altitude
for
altitude
range.
SINGLE-STAGE
ON/OFF
Switch
Regulator
Seal
Cap
Regulator
Adjustment
59SC2A
1/8"
NPT
Inlet
Pressure
Tap
1/8"
NPT
Manifold
Pressure
Tap
A11153
C
NK
BURNER
|
N
ORIFICE
Ag3059
Fig.
54
-
Orifice
Hole
THERMOSTAT
SUBBASE
TERMINALS
WITH
THERMOSTAT
REMOVED
{ANITICIPATOR,
CLOCK,
ETC.,
MUST
BE
OUT
OF
CIRCUIT.)
HOOK-AROUND
AMMETER
40
rurns—”
_
FROM
UNIT
24-V
CONTROL
TERMINALS
EXAMPLE:
5.0
AMPS
ON
AMMETER
_
0.5
AMPS
FOR
THERMOSTAT
40
TURNS
AROUND
JAWS
ANTIGIPATOR
SETTING
AQ6316
Fig.
55
-
Amp. Draw
Check
with
Ammeter

Other manuals for Carrier 59SC2A