SERVICE
sis
If
status
code
recall
is
needed,
briefly
remove
then
reconnect
one
main
limit
wire
to
display
last
stored
status
code.
After
one
status
code
recall
is
completed
component
test
will
occur.
LED
CODE
STATUS
CONTINUOUS
OFF
=
Check
for
1745VAC
at
L1
&
L2,
&
24VAC
at
SEC-1
&
SEC-2,
CONTINUOUS
ON-
Control
has
24VAC
power.
RAPID
FLASHING
-
Line
voltage
(115VAC)
polarity
reversed.
If
twinned,
refer
to
twinning
kit
instructions.
EACH
OF
THE
FOLLOWING
STATUS
CODES
IS
A
TWO
DIGIT
NUMBER
WITH
THE
FIRST
DIGIT
DETERMINED
BY
THE
NUMBER
OF
SHORT
FLASHES
AND
THE
SECOND
DIGIT
BY
THE
NUMBER
OF
LONG
FLASHES.
14
NO
PREVIOUS
CODE
-
Stored
status
codes
are
erased automatically
after
72
hours.
{2
BLOWER
ON
AFTER
POWER
UP
(115VAC
or
24VAC)
»
Blower
runs
for
90
seconds,
if
unit
is
powered
up
during
a
call
for
heat
(R-W
closed)
or
R-W
opens
during
blower
on-delay.
13
LIMIT
CIRCUIT
LOCKOUT
=
Lockout
occurs
if
a
limit
or
flame
rollout
switch
is
open
longer
than
3
minutes.
-
Control
will
auto
reset
after
three
hours.
~
Refer
to
#33
14
IGNITION
LOCKOUT
+
Control
will
auto-reset
after
three
hours,
Refer
to
#34,
21
GAS
HEATING
LOCKOUT
-
Control
will
NOT
auto
reset.
Check
for:
-
Mis-wired
gas
valve
-
Defective
control
(valve
relay)
22
ABNORMAL
FLAME-PROVING
SIGNAL
«
Flame
is
proved
while
gas valve
is
de-energized.
Inducer
will
run
until
fault
is
cleared.
Check
for:
-
Leaky
gas valve
-
Stuck-open
gas
valve
23
PRESSURE
SWITCH
DID
NOT
OPEN
+
Check
for:
-Obstructed
pressure
tubing
-
Pressure
switch
stuck
closed
24
SECONDARY
VOLTAGE
FUSE
IS
OPEN
«
Check
for:
-
Short
circuit
in
secondary
voltage
(24VAC)
wiring,
31
PRESSURE
SWITCH
DID
NOT
CLOSE
OR
REOPENED
-If
LPS
open
longer
than
five
minutes,
inducer
shuts
off
for
15
minutes
before
retry.
If
HPS
remains open
for
one
minute
after
gas valve
closes
(after
three
succesive
trials),
then
furnace
control
will
lockout
for
3
hours
before
retry.
Check
for:
-
Excessive
wind
-Restricted
vent
—-
Defective
inducer
motor
~
Low
inlet
gas
pressure
(if
LGPS
used)
-
Defective
pressure
switch
-
Low
inducer
voltage
(115VAC}
-
Inadequate
combustion
air
supply
-
Proper
vent
sizing
-
Disconnected
or
obstructed
pressure
tubing
-
Condensate
drainage
restricted
or
blocked
If
it
opens
during
blower
on-delay
period,
blower
will
come
on
for
the
selected
blower
off-delay.
33
LIMIT
CIRCUIT
FAULT
-
Indicates
a
limit
or
flame
rollout,
switch
is
open.
Blower
will
run
for
4
minutes
or
until
open
switch
remakes
whichever
is
longer.
If
open
longer
than
3
minutes,
code
changes
to
lockout
#43.
If
open
less
than
3
minutes
status
code
#33
continues
to
flash
until
blower
shuts
off.
Flame
rollout
switch
requires
manual
reset.
Check
for:
—-
Dirty
filter
or
restricted
duct
system
-
Proper
vent
sizing
-
Restricted
vent
—-
Loose
blower
wheel
-
Excessive
wind
-
Defective
blower
motor
or
capacitor
-
Defective
switch
or
connections
-
Inadequate
combustion
air
supply
(Flame
Roll-out
Switch
open).
34
IGNITION
PROVING
FAILURE
-
Control
will
try
three
more
times
before
lock
out
#14 occurs.
If
flame
signal
lost
during
blower
on-delay
period,
blower
will
come
on
for
the
selected
blower
off-delay.
Check
for:
=
Oxide
buildup
on
flame
sensor
(clean
with
fine
steel
wool)
-
Proper
flame
sense
microamps
(.5
microamps
D.C.
min.,
4.0
-
6.0
nominal)
-
Manual
valve
shut-off
-
Control
ground
continuity
-
Gas
valve
defective
or
gas valve
turned
off
-
Low
inlet
gas
pressure
-
Inadequate
flame
carryover
or
rough
ignition
-
Defective
Hot
Surface
Iynitor
-
Flame
sensor
must
not
be
grounded
-
Green/yellow
wire
MUST
be
connected
to
furnace
sheet
metal
45
CONTROL
CIRCUITRY
LOCKOUT
=
Auto-reset
after
one
hour
lockout
due
to;
-
Gas
valve
relay
stuck
open
-
Flame
sense
circuit
failure
-
Software
check
error
Reset
power
to
clear
lockout.
Replace
control
if
status
code
repeats.
COMPONENT
TEST
[aE
To
initiate
the
component
test
sequence
shut
OFF
the
room
thermostat
or
disconnect
the
“R’
thermostat
lead.
Briefly
short
the
TEST/TWIN
terminal
to
the
“Com
24V”
terminal.
.
Status
LED
will
flash
last
status
code
and
then
turn
ON
the
inducer
motor.
The
inducer
+
:
motor
will
run
for
the
entire
component
test.
The
hot
surface
ignitor,
blower motor
FAN
;
speed
(if
equiped)
blower
motor
HEAT
speed,
and
blower
motor
COOL
speed
will
be
turned
ON
for
10-15
seconds
each.
Gas
Valve
and
Humidifier
will
not
be
turned
on.
338309-201
Rev.E
Fig.
56
-
Service
Label
Information
66