4
SPECIFICATIONS
Heating Capacity and Efficiency 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Input
High Heat (BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 120,000
Low Heat (BTUH) 26,000 26,000 39,000 39,000 52,000 52,000 65,000 78,000
Output
High Heat (BTUH) 39,000 39,000 58,000 58,000 78,000 78,000 97,000 117,000
Low Heat (BTUH) 25,000 25,000 38,000 38,000 50,000 51,000 63,000 76,000
Certified Temperature
Rise Range ºF (ºC)
High Heat
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
40 - 70
(22 - 39)
Low Heat
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
30 - 60
(17 - 33)
Airflow Capacity and Blower Data 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Rated External Static
Pressure (in. w.c.)
Heating 0.10 0.10 0.12 0.12 0.15 0.15 0.20 0.20
Cooling 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Airflow Delivery
@ Rated ESP (CFM)
High Heat 815 860 1120 1135 1505 1555 1865 2375
Low Heat 660 660 910 860 1160 1200 1435 1675
Cooling 905 1065 1065 1475 1610 2005 2005 2115
Cooling Capacity (tons)
@ 400, 350 CFM/ton
400 CFM/ton 2 2.5 2.5 3.5 4 5 5 5
350 CFM/ton 2.5 3 3 4 4.5 5.5 5.5 6
Direct-Drive Motor Type Electronically Communicated Motor (ECM)
Direct-Drive Motor HP 1/2 1/2 1/2 3/4 3/4 1 1 1
Motor Full Load Amps 6.8 6.8 6.8 8.4 8.4 10.9 10.9 10.9
RPM Range 600 - 1200
Speed Selections Variable (PWM)
Blower Wheel Dia x Width in. 11 x 7 11 x 8 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11
Air Filtration System
Optional Media Cabinet
Field Supplied Filter
Filter Used for Certified Watt Data KGAWF1506UFR
Electrical Data 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Input Voltage Volts-Hertz-Phase 115-60-1
Operating Voltage Range Min-Max 104-127
Maximum Input Amps Amps 7.5 7.5 7.6 9.2 9.2 11.7 11.8 11.8
Unit Ampacity Amps 10.3 10.2 10.3 12.4 12.4 15.5 15.6 15.6
Minimum Wire Size AWG 14 14 14 14 14 12 12 12
Maximum Wire Length
@ Minimum Wire Size
Feet 36 36 36 29 29 37 36 36
(M) (11.0) (11.0) (11.0) (8.8) (8.8) (11.3) (11.0) (11.0)
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Amps 15 15 15 15 15 20 20 20
Transformer Capacity (24vac output) 40 VA
External Control Power
Available
Heating 24.3 VA
Cooling 34.6 VA
Controls 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Gas Connection Size 1/2" - NPT
Burners (Monoport) 2 2 3 3 4 4 5 6
Gas Valve (Redundant) Manufacturer White Rodgers
Minimum Inlet Gas pressure (in. wc) 4.5
Maximum Inlet Gas pressure (in. wc) 13.6
Manufactured (Mobile) Home Kit not approved for MH use
Ignition Device Silicon Nitride
Limit Control 165 180 165 180 170 200 180 160
Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay) 90 seconds
Communication System None
Thermostat Connections R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
* See Accessory List for part numbers available.
59TP6A