The pumps tted to these units have motors which meet efciency class IE2 for motors < 7.5kW and IE3 for motors > 7.5kW.
The additional electrical data required
(1)
is as follows:
For the low-pressure single pump motors of 30RBM/RBP 160-520 units (option 116T)

(2)

(3)


 180 200 220  300 330  400 430 470 520
1 Nominaleciencyatfullloadandnominalvoltage % 85,7 85,7 85,7 85,7 85,7 87,5 87,5 87,5 89,9 89,9 89,9 89
1 Nominaleciencyat75%offullloadandnominalvoltage % 86,9 86,9 86,9 86,9 86,9 88,2 88,2 88,2 90,4 90,4 90,4 90
1 Nominaleciencyat50%offullloadandnominalvoltage % 86,4 86,4 86,4 86,4 86,4 87,5 87,5 87,5 89,6 89,6 89,6 89,7
2 Eciencylevel - IE3
3 Year of manufacture - This information varies depending on the manufacturer and model at the time of
incorporation.Pleaserefertothemotornameplates.
4 Manufacturer'snameandtrademark,commercialregistration
numberandmanufacturer'sheadoce
- Same as above
5 Product'smodelnumber - Same as above
6 Number of motor poles - 2 2 2 2 2 2 2 2 2 2 2 2
7-1 Nominal shaft power output at full load and nominal voltage (400 V) kW 2,2 2,2 2,2 2,2 2,2 3 3 3 4 4 4 5,5
7-2 Maximum input power (400 V)
(4)
kW 2,80 2,80 2,80 2,80 2,80 3,81 3,81 3,81 4,96 4,96 4,96 6,80
8 Rated input frequency Hz 50 50 50 50 50 50 50 50 50 50 50 50
9-1 Nominal voltage V 3 X 400
9-2 Maximum current drawn (400 V)
(5)
A 4,92 4,92 4,92 4,92 4,92 6,81 6,81 6,81 8,27 8,27 8,27 11,30
10 Nominal speed rps - rpm 48-2900
11 Productdisassembly,recyclingordisposalatendoflife - Disassemblyusingstandardtools.Disposalandrecyclingusinganappropriate
company.
12 Operatingconditionsforwhichthemotorisspecicallydesigned
I-Altitudesabovesealevel m < 1000
(6)
II-Ambientairtemperature °C < 40
IV-Maximumoperatingtemperature °C Please refer to the operating conditions given in this manual or
inthespecicconditionsgivenintheCarrierselectionprograms.
V - Potentially explosive atmospheres - Non ATEX environment
(1) RequiredbyregulationNo.640/2009concerningtheapplicationofdirective2009/125/EContheeco-designrequirementsforelectricmotors.
(2) ItemnumberimposedbyregulationNo.640/2009,annexI2b.
(3) DescriptiongivenbyregulationNo.640/2009,annexI2b.
(4) Toobtainthemaximuminputpowerforaunitwithhydraulicmodule,addthemaximumunitinputpowerfromtheelectricaldatatabletothepumppowerinput.
(5) Toobtainthemaximumoperatingcurrentdrawforaunitwithhydraulicmodule,addthemaximumunitcurrentdrawfromtheelectricaldatatabletothepumpcurrentdraw.
(6) Above1000m,adegradationof3%foreach500mshouldbetakenintoconsideration.
For the low-pressure dual pump motors of 30RBM/RBP 160-520 units (option 116U)

(2)

(3)


 180 200 220  300 330  400 430 470 520
1 Nominaleciencyatfullloadandnominalvoltage % 84,9 84,9 85,7 85,7 87,5 87,5 87,5 87,5 89,9 89,9 89,9 89
1 Nominaleciencyat75%offullloadandnominalvoltage % 86,4 86,4 86,9 86,9 88,2 88,2 88,2 88,2 90,4 90,4 90,4 90
1 Nominaleciencyat50%offullloadandnominalvoltage % 85,9 85,9 86,4 86,4 87,5 87,5 87,5 87,5 89,6 89,6 89,6 89,7
2 Eciencylevel - IE3
3 Year of manufacture - This information varies depending on the manufacturer and model at the time of
incorporation.Pleaserefertothemotornameplates.
4 Manufacturer'snameandtrademark,commercialregistration
numberandmanufacturer'sheadoce
- Same as above
5 Product'smodelnumber - Same as above
6 Number of motor poles - 2 2 2 2 2 2 2 2 2 2 2 2
7-1 Nominal shaft power output at full load and nominal voltage (400 V) kW 1,5 1,5 2,2 2,2 3 3 3 3 4 4 4 5,5
7-2 Maximum input power (400 V)
(4)
kW 1,94 1,94 2,80 2,80 3,81 3,81 3,81 3,81 4,96 4,96 4,96 6,80
8 Rated input frequency Hz 50 50 50 50 50 50 50 50 50 50 50 50
9-1 Nominal voltage V 3 X 400
9-2 Maximum current drawn (400 V)
(5)
A 3,41 3,41 4,92 4,92 6,81 6,81 6,81 6,81 8,27 8,27 8,27 11,30
10 Nominal speed rps - rpm 48-2900
11 Productdisassembly,recyclingordisposalatendoflife - Disassemblyusingstandardtools.Disposalandrecyclingusinganappropriate
company.
12 Operatingconditionsforwhichthemotorisspecicallydesigned
I-Altitudesabovesealevel m < 1000(6)
II-Ambientairtemperature °C < 40
III-Maximumoperatingtemperature °C Please refer to the operating conditions given in this manual or
inthespecicconditionsgivenintheCarrierselectionprograms.
V - Potentially explosive atmospheres - Non ATEX environment
(1) RequiredbyregulationNo.640/2009concerningtheapplicationofdirective2009/125/EContheeco-designrequirementsforelectricmotors.
(2) ItemnumberimposedbyregulationNo.640/2009,annexI2b.
(3) DescriptiongivenbyregulationNo.640/2009,annexI2b.
(4) Toobtainthemaximuminputpowerforaunitwithhydraulicmodule,addthemaximumunitinputpowerfromtheelectricaldatatabletothepumppowerinput.
(5) Toobtainthemaximumoperatingcurrentdrawforaunitwithhydraulicmodule,addthemaximumunitcurrentdrawfromtheelectricaldatatabletothepumpcurrentdraw.
(6) Above1000m,adegradationof3%foreach500mshouldbetakenintoconsideration.