60
COMBINATION RATINGS
AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity EER SEER
4585479 CA16NA061****A CNPV*6024A** 58ME(B,C)120---20 58,000 12.7 14.5
4661851 CA16NA061****A CNPV*6024A** 58MEC100---20 58,000 12.5 14.5
4585474 CA16NA061****A CNPV*6024A** 58MV(B,C)120---20 57,500 12.2 14.0
4661850 CA16NA061****A CNPV*6024A** 58PH*110 ---20 58,000 12.5 14.5
4585478 CA16NA061****A CNPV*6024A** 58PH*135 ---20 58,000 12.7 14.5
4585475 CA16NA061****A CNPV*6024A** 58UVB120---20 57,500 12.2 14.0
4661852 CA16NA061****A CNPV*6024A** 58VLR120---20 58,000 12.0 14.0
4768295 CA16NA061****A CNPV*6024A** 59*N*A120V24**22 57,500 12.0 14.5
4768296 CA16NA061****A CNPV*6024A** 59*P5A120E24**22 57,500 12.0 14.5
4585473 CA16NA061****A CNPV*6024A**+TDR 59,000 12.2 14.0
4661853 CA16NA061****A CNPV*6124A** 58CV(A,X)110---20 58,500 12.5 14.5
4585483 CA16NA061****A CNPV*6124A** 58CV(A,X)135---22 59,000 13.0 15.2
4585484 CA16NA061****A CNPV*6124A** 58CV(A,X)155---22 59,000 13.0 15.2
4585487 CA16NA061****A CNPV*6124A** 58HDV100--- ---20 59,000 12.2 14.0
4585486 CA16NA061****A CNPV*6124A** 58ME(B,C)120---20 58,500 13.0 15.2
4661855 CA16NA061****A CNPV*6124A** 58MEC100---20 58,500 12.5 14.5
4585481 CA16NA061****A CNPV*6124A** 58MV(B,C)120---20 58,500 12.5 14.5
4661854 CA16NA061****A CNPV*6124A** 58PH*110 ---20 59,000 13.0 15.2
4585485 CA16NA061****A CNPV*6124A** 58PH*135 ---20 58,500 12.7 14.5
4585482 CA16NA061****A CNPV*6124A** 58UVB120---20 58,500 12.5 14.5
4661856 CA16NA061****A CNPV*6124A** 58VLR120---20 59,000 12.5 14.5
4768297 CA16NA061****A CNPV*6124A** 59*N*A120V24**22 58,500 12.5 15.0
4768298 CA16NA061****A CNPV*6124A** 59*P5A120E24**22 58,500 12.5 15.0
4585526 CA16NA061****A CSPH*6012A** 58CV(A,X)110---20 58,500 12.7 14.5
4585527 CA16NA061****A CSPH*6012A** 58CV(A,X)135---22 58,500 12.7 14.5
4585528 CA16NA061****A CSPH*6012A** 58CV(A,X)155---22 58,500 13.0 15.2
4585534 CA16NA061****A CSPH*6012A** 58HDV080--- ---20 58,500 12.0 13.7
4585535 CA16NA061****A CSPH*6012A** 58HDV100--- ---20 58,500 12.2 14.0
4585531 CA16NA061****A CSPH*6012A** 58ME(B,C)080---16 57,500 12.5 14.5
4585532 CA16NA061****A CSPH*6012A** 58ME(B,C)100---20 58,000 12.7 14.5
4585533 CA16NA061****A CSPH*6012A** 58ME(B,C)120---20 58,500 13.0 15.2
4585523 CA16NA061****A CSPH*6012A** 58MV(B,C)080---20 58,000 12.0 13.7
4585524 CA16NA061****A CSPH*6012A** 58MV(B,C)100---20 57,500 12.2 14.0
4585525 CA16NA061****A CSPH*6012A** 58MV(B,C)120---20 58,000 12.5 14.0
4585529 CA16NA061****A CSPH*6012A** 58PH*110---20 58,500 12.7 14.5
4585530 CA16NA061****A CSPH*6012A** 58PH*135---20 58,500 12.7 14.5
4585537 CA16NA061****A CSPH*6012A** 58VLR120---20 58,500 12.5 14.5
4585536 CA16NA061****A CSPH*6012A** 58VMR120---20 58,000 12.2 14.0
4768303 CA16NA061****A CSPH*6012A** 59*N*A120V24**22 58,000 12.5 15.0
4768304 CA16NA061****A CSPH*6012A** 59*P5A120E24**22 58,000 12.0 14.5
4585538 CA16NA061****A CSPH*6012A** OVLAAB060154 59,000 11.7 13.5
4585522 CA16NA061****A CSPH*6012A**+TDR 59,000 12.2 14.0
4585539 CA16NA061****A FB4CNF060 58,000 12.7 14.5
4585542 CA16NA061****A FE4ANB006+UI 59,000 13.2 15.2
4585543 CA16NA061****A FV4CNB006 59,000 13.2 15.2
4585541 CA16NA061****A FX4DN(B,F)061 59,500 13.2 15.2
4585540 CA16NA061****A FY5BNB060 59,000 12.0 13.5
{ Tested combination
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time--- Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
TXV — Thermostatic Expansion Valve
UI — User Interface
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE
computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.