Table 6 Accessory Usage
ACCESSORY
REQUIRED FOR LOW--- AMBIENT
COOLING APPLICATIONS
(Below 55F/12.8_C)
REQUIRED FOR LONG LINE
APPLICATIONS*
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles/3.22 km)
Ball Bearing Fan Motor Ye s { No No
Compressor Start Assist Capacitor and Re lay Ye s Ye s No
Crankcase Heater Ye s Ye s No
Evaporator Freeze Thermostat Ye s No No
H a r d S h u t --- O f f T X V Ye s Ye s Ye s
Liquid Line Solenoid Valve No No No
Motor Master
or Low---ambient Pressure Switch Ye s No No
Support Fee t Recommended No Recommended
Winter Start Control Ye s No No
* For tubing line sets between 80 and 200 ft. ( 24.38 and 60.96 m) a nd/or 35 ft. (10.7 m) vertical differential, refer to Residential Piping an d Longline Guideline.
{ Additional requirement for Low ---Ambient Controller (full modulation feature) MotorMasterr Control.
Always Ask For
24 VAC HOT
24 VAC COM
R
C
G
W/W1
Y/Y2
R
C
C
A/C
THERMOSTAT
Typical
FAN COIL
AIR
CONDITIONER
G
W2
HEAT STAGE 1
COOL STAGE 1
INDOOR FAN
24 VAC HOT
24 VAC COM
R
C
G
W/W1
Y/Y2
R
C
C
A/C
THERMOSTAT
Typical
FURNACE
AIR
CONDITIONER
Y
G
W
HEAT STAGE 1
COOL STAGE 1
INDOOR FAN
A02326
LEGEND
24-V FACTORY WIRING
24-V FIELD WIRING
FIELD SPLICE CONNECTION
CONTACTOR
C
A97368
Fig. 8 -- Generic Wiring Diagrams
(See Thermostat Installation Instruction
for specific unit combinations)
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: CA13---16N---02SI
R e p l a c e s : C A 1 3 --- 1 6 N --- 0 1 S I