53
CONNECTING REFRIGERANT PIPING
18.5 DESCRIPTION OF REFRIGERANT CONNECTIONS OF OUTDOOR UNIT
(1) Suction flare valve. (2) Suction service valve.
(3) Suction port to open & close. (4) Cap for suction service valve.
(5) Cap for Suction port. (6) Liquid flare valve.
(7) Liquid port to open & close. (8) Cap for liquid port.
18.6 DESCRIPTION OF REFRIGERANT CONNECTIONS OF INDOOR UNIT
Refrigerant
Connections Details
18.7 DESCRIPTION OF REFRIGERANT CONNECTIONS
OF REFERIGERANT PIPING LINES
(1) Suction piping line
(2) Liquid piping line
18.8 CUTTING AND FLARING TOOLS
Make sure that have the required tools available before preparing refrigerant piping lines
Indoor Unit
Half Union
Suction
Half Union
Liquid
Pipe Cutter
Flare Tool
Refrigerant
Connections
(1)
(2)
4
5
2
3
1
7
6
8