Table 7A — Compressor Electrical Data, 30HXC Units
LEGEND
*Units are shipped with wye-delta start as standard. Across-the-line start is not available.
UNIT SIZE 30HXC
NAMEPLATE
V-Hz
(3 Phase)
COMPRESSOR NUMBERS
A1 B1
RLA LRA RLA LRA
076-XL
208/230-60 * * * *
230-60 * * * *
460-60 44.3 330 44.3 330
575-60 35.4 264 35.4 264
380-60 53.7 365 53.7 365
230-50 * * * *
380/415-50 55.8 344 55.8 344
076-WD
208/230-60 98.1 209 98.1 209
230-60 88.3 209 88.3 209
460-60 44.3 104 44.3 104
575-60 35.4 83 35.4 83
380-60 53.7 115 53.7 115
230-50 92.1 174 92.1 174
380/415-50 55.8 109 55.8 109
086-XL
208/230-60 * * * *
230-60 * * * *
460-60 53.6 330 44.3 330
575-60 42.8 264 35.4 264
380-60 64.9 365 53.7 365
230-50 * * * *
380/415-50 67.7 423 55.8 344
086-WD
208/230-60 118.6 209 98.1 209
230-60 106.7 209 88.3 209
460-60 53.6 104 44.3 104
575-60 42.8 83 35.4 83
380-60 64.9 115 53.7 115
230-50 111.8 213 92.1 174
380/415-50 67.7 134 55.8 109
096-XL
208/230-60 * * * *
230-60 * * * *
460-60 65.5 405 44.3 330
575-60 52.3 324 35.4 264
380-60 79.2 448 53.7 365
230-50 * * * *
380/415-50 81.7 506 55.8 344
096-WD
208/230-60 144.9 256 98.1 209
230-60 130.4 256 88.3 209
460-60 65.5 128 44.3 104
575-60 52.3 102 35.4 83
380-60 79.2 141 53.7 115
230-50 134.9 255 92.1 174
380/415-50 81.7 160 55.8 109
106-XL
208/230-60 * * * *
230-60 * * * *
460-60 79.2 485 44.3 330
575-60 63.3 388 35.4 264
380-60 95.9 536 53.7 365
230-50 * * * *
380/415-50 97.8 605 55.8 344
106-WD
208/230-60 175.4 307 98.1 209
230-60 157.9 307 88.3 209
460-60 79.2 153 44.3 104
575-60 63.3 123 35.4 83
380-60 95.9 169 53.7 115
230-50 161.7 305 92.1 174
380/415-50 97.8 191 55.8 109
LRA Locked Rotor Amps
RLA Rated Load Amps
WD Wye-Delta Start
XL Across-the-Line Start