15
62--61177--01
M
a
x
i
m
m
a
m
e
r
a
e
f
r
e
r
a
t
i
e
i
m
e
t
M
a
x
i
mum amperage
f
or ope rat
i
on equ
i
pment
Operating voltage XARIOS 500--04 XARIOS 600
230/1/50Hz 17.2 amps 17.2 amps
230/3/60Hz 16.6 amps 16.6 amps
208-230/1/60Hz 20 amps 20 amps
400/3/50Hz 8amps 10.7 amps
Operating voltage XARIOS 300--05 XARIOS 350--05
230/3/50Hz/60Hz Not available 8.8 amps
400/3/50Hz/60Hz 4.9 amps 5amps
230/1/50Hz 5.6 amps 11 amps
208/230/1/60Hz Not available 11.7 / 10.7 amps
115/1/60Hz Not available 18.3 amps
Operating voltage XARIOS 150--04 XARIOS 200--04
400/3/50Hz 2.4 amps 2.4 amps
230/1/50Hz 8amps 8amps
208/230/1/60Hz Not available 9amps
c. The unit connection cable must be fitted with a ground connection. The cable must be connected to earth.
d. When performing service and/or maintenance procedures on a refrigeration unit, make certain that the
unit is disconnected from the power source and that the keypad correctly indicates “OFF”, and that it is
impossible for the unit to start up automatically during the maintenance operation.
e. The user is liable for ensuring that the above measures are taken.
f. An internal sensor protects the standby compressor from overtensions or overheating.