(1) Main Display (Weight Display)
A. Displaying the value of gross or net weight.
B. Displaying error messages for any abnormal motion or weigh setup error/
C. Displaying the status value for the Set Mode and weight setup mode.
(2) Status Display (Lamp)
LED Lamp LCD Status Display Descriptions
Stable
The weighed weight is stable.
Net weight
The current display of weight is a net weight.
Zero point
The current weight is 0 kg.
Hold
The current status is under hold.
Displayed when the battery should be charged (chargeable
battery).
-
High limit
The weight is heavier than the upper limit.
-
Low limit
The display of lower limit is lit if the value set at F50 is
smaller than the lower limit, or greater than the lower limit or
smaller than the upper limit.
-
Normal
The weight is greater than the lower limit and smaller than the
upper limit.
Tare
The current status is at the tare status.
Communicat
ion
The current status is at the communication status.
-
Summatio
n lamp
The current weight is the value of summation.
-
Quantity
lamp
The current mode is at the count mode.
-
Percent
lamp
The current mode is at the percent mode.