36
F06
Function Setting vibration filter
Display Meaning
F06. 00
Vibration filter OFF
F06. 10 Compensation for the vibration value of 5 divisions (0.5d * 10)
Setting range
(00 ~ 99)
F06. 99 Compensation for the vibration value of 49.5 divisions (0.5d * 99)
Note 1. Apply this function to a place with heavy vibrations.
(The display response speed becomes slower when the vibration filter is applied.)
Note 2. This function should be adjusted appropriately to the site while the speed of weight variations in
F04 is being lowered little by little.
F07
Function Setting Motion Detection Condition
Display Meaning
F07. 1 The 'Stable' lamp is lit if the weight changes within 0.5 division.
F07. 2
The 'Stable' lamp is lit if the weight changes within 1 division.
Setting range
(1 ~ 99)
F07. 10 The 'Stable' lamp is lit if the weight changes within 5 division.
F08
Function Setting Automatic Zero Tracking Compensation
Display Meaning
F08. 0 Automatic zero function is not used.
F08. 1 If it changes slowly to 0.5 divisions or less, it is compensated.
F08. 2
If it changes slowly to 1.0 divisions or less, it is compensated.
Setting range
(0 ~ 9)
F06. 9 If it changes slowly to 4.5 divisions or less, it is compensated.
Note 1. This function compensates zero automatically if the weight at the zero point does not exceed the
division in a certain range within a specific time.
Ex) If F08 is set to "4" when the maximum displayed division is 120.0kg and the value of a division is
set to 0.05kg;
If a greater change than 100g occurs
within 0.75 seconds,, the chan
g
ed
2.0digit
(0.1Kg)
0.75 Sec