42
Serial Communication COM1 Function
F28
Function Set COM1 Baud Rate
Display Meaning
F28. 0 600 bps
F28. 1 1200 bps
F28. 2 2400 bps
F28. 3 4800 bps
F28. 4
9600 bps
F28. 5 19200 bps
F28. 6 38400 bps
F28. 7 57600 bps
Setting range
(0 ~ 8)
F28. 8 115200 bps
F29
Function Set COM1 - Usage
Display Meaning
F29 0
Connect to a printer
Setting range
(0 ~ 1)
F29 1 Connect to a computer or auxiliary display
* If F29: 0 and F33 : 0, "ERR-Set" is displayed with no print.
F30
Function Set COM1 - Output Format
Display Meaning
F30 0
22 bytes for CA
F30 1 10 bytes for CA
Setting range
(0 ~ 2)
F30 2 18 bytes for AND
F31
Function Set COM1 - Output Mode
Display Meaning
F31 0
No data out
F31 1 Transmission for both the stable and instable time (stream mode)
F31 2 One time transmission after the weight is stabilized.
F31 3
Transmission only if data is requested.
* Data request signal: device ID (F26) _ 1 byte communication
(Data on request: 1= 0x01, 10 = 0x0A)
Setting range
(0 ~ 4)
F31 4 Response to the data request - Command Mode
Set the value of F31 to '1' or more if the print mode is used.