60
7-2. PCS MODE
7-2-1. PCS MODE Sample Input Method
Step Display Screen and Key Input
Load
Tray
Descriptions
1
Press
key for about 3 seconds in the PCS Mode.
Empty
2 Screen display: “1.SAMPL” characters are blinking.
3
If key is pressed, “1. SAMPL” characters are blinking.
If key is pressed, “2. WEIGH” characters are blinking.
Select the
input method
as desired.
4
Press + keys.
5
Screen display: A/D value is displayed after “SAMPLE” ->
“LoAd” is shown.
(Wait until the weight is stable.)
Sample
Put samples
on the load
tray
6
Press key
Sample
Save sample
weight
7 Screen display: “SUCCES” -> “NUMBER” is displayed. Sample
8
Enter the number of samples using ~ keys,
and then press
key.
(Ex) If 10kg (sample) and 10 pieces, then the unit weight
becomes 1kg.
Sample
9 Screen display: It moves to PCS Mode after displaying “End”. Sample
Note 1. The current weight is displayed when key is pressed during operating “1. PCS
MODE”.
Note 2. If the value of 1 PCS is smaller than 0.7 divisions of maximum resolution capacity
when the number of samples is entered, Err-21 is displayed.