7-3. PERCENT MODE
7-3-1. Percent Mode Sample Input Method
Step Display Screen and Key Input
Load
Tray
Descriptions
1
Press
key for about 3 seconds in the Percent Mode.
Empty
2 Screen display: “1.SAMPL” characters are blinking.
3
If key is pressed, “1. SAMPL” characters are blinking.
If key is pressed, “2. WEIGH” characters are blinking.
Select the
input method
as desired.
4
Press + keys.
5
Screen display: A/D value is displayed after “SAMPLE” ->
“LoAd” is shown.
(Wait until the weight is stable.)
Sample
Put samples
on the load
tray
6
Press key
Sample
Save sample
weight
7 Screen display: “SUCCES” -> “NUMBER” is displayed. Sample
8
Enter the number of samples using ~ keys,
and then press
key.
(Ex) If 10kg (sample) and 10 pieces, then the unit weight
becomes 1kg.
Sample
9
Screen display: It moves to Percent Mode after displaying
“End”.
Sample
Note 1. The current weight is displayed when key is pressed during operating in the
Percent Mode.
Note 2. If the value of 1 PCS is smaller than 0.7 divisions of maximum resolution capacity
when the number of samples is entered, Err-21 is displayed.