21
4-1. Weight Setup(Calibration) Menu (CAL1 CAL9)
CAL 1 : Maximum capacity calibration
CAL 2 : Minimum division calibration
CAL 3 : Zero-set and span calibration
CAL 4 : Hopper weight setting
CAL 5 : Direct calibration
CAL 6 : Zero adjustment
CAL 7 : Factor calibration
CAL 8 : Gravity adjustment
CAL 9 : Setting dual range
CAL 1
CAL 1-1
Function : Setting Unit(Unit)
Range of set value : 1 ~ 3
Used key
Display
Descriptions
Using numeric keys ~ Enter
Unit.
= Set, =Cancel
1. kg
Unit : kg
2. ton
Unit : ton
3. gram
Unit : g
CAL 1-2 (Maximum capacity calibration)
Function: Setting Maximum Value
Range of set value: 1 ~ 99,999
Used key
Display
Descriptions
Using numeric keys ~
Enter maximum weight
= Set, =Cancel
C= 10000
Max value = 10000 kg
C= 10
Max value = 10 kg
Reference 1. The maximum capacity of the weighing scale can measure and display.