6. Rear Panel
CONTROL I/O
LOADCELL
OPTION
T250mA
L250V
COM2
AC
COM1
COM1
RS-232 cable( 2 : TxD, 3 : RxD, 5,7 : Gnd )
- F33 = 1 ~ 4 function is enable (both of Set-point and Set-
mode) to read and write
- Computer, sub-display and printer
COM2
RS-232 cable( 2 : TxD, 5,7 : Gnd)
- F36 = 1 ~ 2 function is enable to read only
RS-485/422 cable( 6 : Rx+, 7 : Rx-, 8 : Tx+, 9 : Tx- )
- F36 = 1 ~ 4 function is enable(Set-point) to read and write
LOAD CELL
Port for connecting. 4-wires, 6-wires load cell
External
input
ZERO, TARE,START,STOP,*,ENTER key
CONTROL I/O
External
output
External output for batching operation
OPTION When option is used, please connect
AC 100 ~ 240VAC are available
FUSE T250mA L250V