4) Error Message (In CAL Mode)
Error 20
Reason
The resolution exceeds 1/10,000
Solution
Lower the resolution.
The resolution = allowed weight/one division.
Modify the allowed weight in CAL1 or modify the division in CAL2 so that
the resolution is below 1/10,000
Error 22
Reason
The weight for span calibration is lower than 10% of the maximum
capacity of the indicator
Solution
Set the weight for span calibration in CAL 3 to be greater than 10% of the
maximum capacity
Error 23
Reason
The weight for span calibration exceeds 100% of the maximum capacity
of the indicator
Solution
Set the weight for span calibration to be within the maximum capacity of
the indicator in CAL 1
Error 24
Reason
Span value is too low
Solution
Load cell is damaged or setting of current resolution is not possible.
Calibrate with less resolution