2
8
F05
FUNCTION : Motion Detection Condition
DISPLAY DESCRIPTION
F05 12
Stable lamp is off even with the change of only 1 division for 1
sec.
F05 56
Stable lamp is on with changing of the weight below 5 division
for 3sec.
Set value
( 00 ~ 99 )
F05 88
Stable lamp is on with changing of the weight below 8 division
for 4sec.
Note 1. The first digit indicates division and the second digit indicates sec.
but have to divide it into 2 on the display.
F06
FUNCTION : Automatic Zero Tracking Compensation
DISPLAY DESCRIPTION
F06 0
None
F06 1
0.5 digit
F06 5
2.5 digit
Set value
( 0 ~ 9 )
F06 9
4.5 digit
Auto-zero tracking will remove small
variations automatically
F07
FUNCTION : Weight backup
DISPLAY DESCRIPTION
F07 0 Weight backup is OFF
Set value
( 0 , 1 )
F07 1 Weight backup is ON
Note 1. Memorize the current weight at sudden power failure.
F08
FUNCTION : Set Zero Range
DISPLAY DESCRIPTION
F08 0
Zero key is operated within 2% of max. weight
Set value
( 0, 1 )
F08 1
Zero key is operated within 10% of max. weight