35
(D, ID : 00~99, CR:0x0d, LF:0x0a)
It is impossible to test with Print Key ( + Total Sum Print Key) ( Only possible when F35 = 0)
Format 1 [ Set Point Write :: COM1/COM2 Port available ]
Write the Set-Point values to the CI-6000A with PC
- Writing(Command) & Response Format
Note 1 : When you input the Set Point Value, you have to input without decimal point
Format 2 [ Set Point Read :: COM1/COM2 Port available ]
Read the Set-Point values from CI-6000A with PC
- Command Format
0 1 2 3 4 5 6
D ID H T CR LF
- Response Format
Note 1 : All of Set Point Values are numeric without decimal point.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
D ID H A Set Point Code , Zero Band ,
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
Opt. Preli, Weight , Preliminary Weight ,
Final Weight
34 35 36 37 38 39 40 41 42 43 44 45 46
, Free Fall Weight ,
Hi Limit Weight ,
47 48 49 50 51 52 53
Lo Limit Weight CR LF
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
D ID H T Set Point Code , Zero Band ,
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
Opt. Preli, Weight , Preliminary Weight ,
Final Weight
34 35 36 37 38 39 40 41 42 43 44 45 46
, Free Fall Weight ,
Hi Limit Weight ,
47 48 49 50 51 52 53
Lo Limit Weight CR LF