39
F43
FUNCTION : Printer Format
DISPLAY DESCRIPTION
F43 0 Printing format 0
F43 1 Printing format 1
Set value
( 0 ~ 2 )
F43 2 Printing format 2
Form 0
Date, Time
Serial No., Net weight
Form 1
Date, Time
Serial No., Net weight
Form 2
Date, Time
Gross weight, Tare weight,
Tare weight
02. 1. 1 12:30
001, 50.0 kg
002, 100.0 kg
003, 200.5 kg
-----------------------------------
TOTAL 350.5kg
02. 1. 1 12:30
001, 50.0 kg
02. 1. 1 12:40
002, 50.0 kg
02. 1. 1 12:50
003, 50.0 kg
-----------------------------------
TOTAL 150.0kg
02. 1. 1 12:30
Gross : 1000.0 kg
Tare : 0.0 kg
Net : 1000.0 kg
02. 1. 1 12:40
Gross : 2000.0 kg
Tare : 500.0 kg
Net : 1500.0 kg
-----------------------------------
Net TOTAL 2500.0kg
Note 1. The serial number is initialized to 001 after total printing or power off and on.
F44
FUNCTION : Input user's Information to Printing Format
DISPLAY DESCRIPTION
P12-065
Set ‘A’ (ASCII code 65) in 12
th
data
P00-032
Set blank to 0th character
This 0th code decides to print dead message.
Used key
:
Data
Designation *
key :
Increase
coordinate
P18-255
Set 255 to 18th character.
This code indicates the end of data to be printed.
Note 1. You can add users information in printing format.
(Ex : Company name, phone no.)
Note 2. The range of coordinate is from 0 to 71. 0th code determines whether head message is
printed or not.(032 : print, others : Do not print) Actually 1
st
data to 255 is printed.
Note 3. Designate as follows if you want to add company name “CAS” on print format.
P00-032( ASCII code 32 : Data start), P01-067( ASCII code 67 : character C)