42
Options
F55
FUNCTION : Select of Option
DISPLAY DESCRIPTION
F55 0 Do not use
F55 1 Analog Out(Option 1,2)
Set value
( 0 , 2 )
F55 2 BCD Out(Option 3)
F56
FUNCTION : Output Logic – BCD Out
DISPLAY DESCRIPTION
F56 0 Positive Logic
Set value
( 0 , 1 )
F56 1 Negative Logic
F57
FUNCTION : Analog Output Adjustment at Display Zero
DISPLAY DESCRIPTION
L 00000 0mA, 0V
L 04000 4.000mA, 2V
Set value
( 0~4000 )
L 04015 4.015mA, 2.007V
F58
FUNCTION : Analog Output Adjustment at Maximum Capacity
DISPLAY DESCRIPTION
H 10000 10mA, 4.16V
H 20000 20.000mA, 8.33V
Set value
( 0~24000 )
H 24000 24.000mA, 10V