46
TEST 7
FUNCTION : Analog Output Test
KEY DISPLAY DESCRIPTION
tESt 7 TEST 7 condition
Hi Lo (Hi) (Lo)
HiGH
HiGH : Output maximum weight.
(Adjust to 20mA)
: Output high value
(20mA)
: Output high value
(20mA)
ENTER: Go to menu
Selection mode
Zero
ZEro : Output zero value
(Adjust to 4mA)
TEST 8
FUNCTION : BCD Output Test
KEY DISPLAY DESCRIPTION
tESt 8 TEST 8 condition
ALL ON The state of All Output is ON (Defult)
: All output is ON
: All output is OFF
ENTER: Go to menu
Selection mode
ALL OFF The state of All Output is OFF