5) How to input the set-point value
There are four ways to input the set-point value
First way (F50 = 0 )
To enter set-point, press the * key for 2 seconds in weighing mode
Note 1. Set F50 to 0 in set mode
Note 2. Shift the position of cursor with , key and enter set value with , key to
go to next step, press the * key
STEP DISPLAY DESCRIPTION
Point
ZEro bA
STEP1
1 - 00000
Zero Band
Shift the position of cursor with
, key and
Enter Zero band value with
, key
To go to next step, press the * key
oP - Pre
STEP2
2 - 00000
Optional Preliminary
Input first weight
PrELiM
STEP3
3 - 00000
Preliminary weight
Input Preliminary weight
FinAL
STEP4
4 - 00000
Final weight
Input final weight
FALL
STEP5
5 - 00000
Free Fall Weight
Input free fall weight
H - LiMit
STEP6
6 - 00000
High Limit Weight
Input high limit weight
L - LiMit
STEP7
7 - 00000
Low Limit Weight
Input low limit weight
Second way (F50 = 0 )
Enter set value from F1 to F17 in set mode.
F11 : Zero Band
F12 : Optional Preliminary Weight
F13 : Preliminary Weight
F14 : Final Weight
F15 : Free Fall Weight
F16 : High Limit Weight
F17 : Low Limit Weight
Third way
Enter set-point by using RS-232, RS-485 Communication
Set F33 to 4 in set mode. Refer to set mode. (F33)