51
6) Set-point Condition
Output is done according to the following condition in batching operation.
MODE OUTPUT CONDITION
COMMON Zero band output GROSS weight Zero band
NORMAL
Optional preliminary
weight output
NET weight Final weight – Optional preliminary weight
Loss – in
Optional preliminary
weight output
GROSS weight > Optional preliminary weight
COMMON
Preliminary
weight output
NET weight Final weight - Preliminary weight
COMMON
Final weight
Output
NET weight Final weight - Free fall weight
COMMON
High limit weight
Output
NET weight > Final weight + High limit weight
COMMON
Low limit weight
Output
NET weight < Final weight - Low limit weight
7) Batching Operation
You can select batching operation method in set mode, F20.
a. USER PROGRAM CONTROL MODE
Normal Batching
Loss-in-Weight Batching
b. AUTOMATIC PROGRAM CONTROL MODE
Normal Batching
Loss-in-Weight Batching