6
4
- Device ID : Transmit 1 byte of device ID so that the receiver can receive data
selectively which indicator send.(Device ID is set in F30 .)
- Lamp condition byte : Indicate on/off
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
1 Stable 0 Hold Print Gross Tare Zero
- Data(8 byte) : If 13.5kg, Each ASCII code ‘0’, ‘0’, ‘0’, ‘0’, ‘1’, ‘3’, ‘.’, ‘5’
is transmitted by 8 byte.
- Output error message
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
E R R Error code CR LF
10 bytes of CAS
- Data bit : 8, Stop bit : 1, Parity bit : None
- Code : ASCII
- Transmission data format (10 BYTE)
18 bytes of AND
- Data bit : 8, Stop bit : 1, Parity bit : Even
- Code : ASCII
- Transmission data format (18 BYTE)
. .
DATA (8byte
)
CR LF
└──┘ └──┘ └──┘
US(Unstable) GS(GROSS weight) Unit (kg/t)
ST(Stable) NT(NET weight)
OL(Overload)
DATA (8 byte) CR LF