66
COM2 RS-422 Connection
COM 2 - OUT (+) : 8pin, OUT(-) : 9pin
IN(+) : 6pin, IN(-) : 7pin
- Transfer Mode : Same to the RS-232C interface
F30 Device ID 00 ~ 99
F34 Baud Rate 600,1200,2400,4800,9600,19200bps
F36 Output Mode Stable, Stable or Unstable, Command mode
Data Format : Same to the RS-232C interface(Only Tx of Indicator)
- How to connect to the RS-485 port
Rx(+):IN(+) ---
Tx(+):OUT(+)
---
DATA +
( TRX +)
- - - - - - - - - - - -
Rx(-):IN(-)
---
- - - - - - - - - - - -
Tx(-):OUT(-) ---
DATA -
( TRX -)
RS –
232C
PC
9pin port (Male) RS-485 Convertor
RS-485 port of CI-6000A
- How to connect to the RS-422 port
TX+ :Out(+)
------- Rx+
TX- :Out(-)
------- Rx- ----------------
RX+ : IN(+)
------- Tx+ ----------------
RX- : IN(-)
------- Tx-
RS-
232C
PC
9pin port (Male) RS-422 Convertor
RS-422 port of CI-6000A