69
OP-2 Analog Output Interface (0-10V)
Set F56 to 1 in set mode.
Specification
Output Voltage
0 – 10V
Resolution
More than 1/2000
Temperature Coefficient
0.01%
The output voltage is 0V when the display weight is "0".
And the output voltage is 10V when the display weight is maximum capacity of the indicator.
Fixing or Flexibility Setting Set Mode
SW4 SW5 SW1 SW2 F57(Min) F58(Max)
Output
Current
Flexibility 0 0 0 0 0000 24000 0 – 10V
You have to set zero(0) of the SW1, SW2, SW4 and SW5
SW1 SW2 Output
0 0 0 – 10V