OP-3 BCD Output Interface
Parallel BCD output is the interface that transmits the weight as BCD code.
Inner circuit of input/output circuit is electronically disconnected by photo-coupler
Set F55 to 2 in set mode.
Transmission mode
F56 Output Logic Positive Logic, Negative Logic
Pin Connection
PIN SIGNAL PIN SIGNAL
1 Ground (GND) 26 High : Net, Low : Gross
2 1 x 10
0
27 N.C.
3 2 x 10
0
28 N.C.
4 4 x 10
0
29 N.C.
5 8 x 10
0
30 N.C.
6 1 x 10
1
31 N.C.
7 2 x 10
1
32 N.C.
8 4 x 10
1
33 N.C.
9 8 x 10
1
34 N.C.
10 1 x 10
2
35 N.C.
11 2 x 10
2
36 N.C.
12 4 x 10
2
37 External Vcc
13 8 x 10
2
38 N.C.
14 1 x 10
3
39 External Vcc
15 2 x 10
3
40 N.C.
16 4 x 10
3
41 N.C.
17 8 x 10
3
42 High : +, Low : -
18 1 x 10
4
43 Decimal point : 10
1
19 2 x 10
4
44 Decimal point : 10
2
20 4 x 10
4
45 Decimal point : 10
3
21 8 x 10
4
46 Over Load
22 1 x 10
5
47 N.C.
23 2 x 10
5
48 N.C.
24 4 x 10
5
49 Busy
25 8 x 10
5
50