41
PRT/*
SET #5
4
C
5) C Label
C
PRT/*
5
Input the SET No.
PRT/*
0
0 = Gap Labels
1 = Continuous Strip
How to program the CLabel
1) To go to PROGRAM mode, press the number 1 key then the MODE key.
2) Press key five times.
3) The WEIGHT display shows “SEt”.
4) Press the PRT/*key and the display shows “SEt EntEr 0”.
5) Press 4 key and PRT/* key.
6) The display shows “LAbEL EntEr 1”
7) To program CLabel, press “5” key. The display shows “CLAbEL 0”
8) Press the number “0” key for Gap type labels or the number “1” key for Continuous Strip
type labels and then press the PRT/* key.
9) The display shows “LAbEL EntEr”. To go to SET menu, press C key.
Note: When changing between Gap and Continuous type labels you should always reboot the
scale.