33
F08
FUNCTION : Hold type
VF DISPLAY SUB DISPLAY DESCRIPTION
0 Average Hold
1 Peak Hold
Set value
(0, 1)
2
F08 HoLd
Sampling Hold
Note 1. Average hold : Compute the average weight of oscillating weights.
Peak hold : Compute the maximum weight among oscillating weights.
Sampling hold : Compute the moment weight of oscillating weights.
F09
FUNCTION : Average hold time
VF DISPLAY SUB DISPLAY DESCRIPTION
01 0.1 sec.
Set value
(01~99)
99
F09 H-tlME
9.9 sec.
F10
FUNCTION : Digital filter (Speed control of weight display)
VF DISPLAY SUB DISPLAY DESCRIPTION
0
±2 % : zero key is operated within
±2 % of maximum weight
Set value
(0, 1)
1
F10 rAnGE
±10 % : zero key is operated
within ±10 % of maximum weight
F11
FUNCTION : Conditions of zero and tare key (stable/unstable)
VF DISPLAY SUB DISPLAY DESCRIPTION
oFF
Zero, Tare key is operated when
the scale is stable.
Set value
(oFF~on)
on
F11 Zt-C
Always
Note 1. On and Off are alternately displayed by pressing the key.