15
7. Installation & Connection
※This is L/C connector wire color enclosed with the product
1) Load cell connection
Connect load cell connector to load cell port which is in the backside of the indicator.
* Connecting method
Note 1. In case of 4 wires load cell, connect EX+ with SEN+, and connect EX- with SEN-.
Note 2. Wire color can be different depending on the load cell’s manufacturer or it’s model.
* Load cell output to Resolution
9V impression to loadcell
Max. load cell output
Recommended resolution
2.4 mV 1/2,000 (Max.)
4.8 mV 1/4,000 (Max.)
6.0 mV 1/5,000 (Max.)