19
CAL 3
FUNCTION : Setting Weight In Span
RANGE 1 ~ 99,999 kg/lb
Key Display Description
▲ : Increase of no.
◀ : Shift of digit.
Enter : Store and
move to the next menu.
CAL 3
Maximum
Capacity of CAL 1
(ex : 10000)
Setting weight
(ex : 100)
CAL 3 condition
10000 kg / lb
100 kg / lb
Ref 1. The weight shall be within the range of 1 % ~ 100 % of maximum weight.
Ref 2. If the Setting Weight is under the 1% of the Maximum Capacity,
Error message ("ERR 22") will occur.
Ref 3. If the Setting Weight over the Maximum Capacity,
Error message ("ERR 23") will occur.
Ref 4. If you press Enter key, it will be moved to CAL 3.
CAL 4
FUNCTION : Zero Calibration Function
Key Display Description
Enter : Zero
Calibration and
move to the next menu.
CAL 4
UnLOAd
A/D value
- - - -
GOOd
CAL 4 condition
Unload the tray and press Enter key
Display A/D Value.
Press Enter Key.
Under zero calibration
Zero Calibration is completed.
The program moves into Span
Calibration automatically.
Ref 1. If Zero calibration is done without any error, GOOD message is displayed
and program automatically moves to CAL 5.
Ref 2. If the zero value is too high, ERROR message (ERR 26) is displayed.
Ref 3. Zero calibration can be done independently. If you press ZERO key instead of
Enter key, zero calibration will perform.
After that, it will be moved to SAVE & EXIT mode.