DISTRIBUTIONSYSTEMS-PRIMARYHYDRAULICPOWERSYSTEM
RCPH09CWL339AAD4
CAS10280Flowmeter
PRIMARYHYDRAULICPOWERSYSTEM-Generalspecication
TypeofoilCASEAKCELAAW68HYDFLUIDMAT3508
Temperatureofhydraulicoilwhentesting52-79°C(125-175°F)
Neutralsystempressure
12-15bar(180-220psi)at2000RPM
Mainreliefvalvepressure
Allmodelsat2000RPM
203-214bar(2950-3100psi)
Circuitreliefvalves
AandBportsripper/auxiliarysection
214-227bar(3100-3300psi)withhandpump
Dozerbladeliftspeed457mmsecond(18insecond)
Dozerbladelifttime(measurefromgroundleveltofull
height)
2seconds
8426083121/08/2009
A.10.A/
5