Minimum fuel temperature limits in the fuel tanks:
Fuel
Minimum permissible fuel
temperature in the fuel
tank before takeoff
Minimum permissible fuel
temperature in the fuel
tank during the flight
Jet A-1, JET A,
Fuel No.3 JP-8,
JP-8+100, TS-1
- 30°C
- 35°C
Diesel
Greater than 0°C
- 5°C
Table 2-5 Min. Fuel Temperature Limits in the fuel tank
WARNING: The following applies to Diesel and Jet A-1 mixtures in
the tank:
As soon as the proportion of Diesel in the tank is more
than 10%, the fuel temperature limits for Diesel operation
must be observed. If there is uncertainty about which fuel
is in the tank, the assumption should be made that it is
Diesel.