4) Press the igniter button (fig. 1 D) fully in.
- The fan will change to high speed to purge the com-
bustion chamber, and the pump will stop.
- After approximately 14 seconds the spark generator
creates a continuous spark to light the pilot.
- When the pilot is alight, viewed through the sight
glass, wait a further 5 seconds before slowly relea-
sing the button.
- If the pilot goes out wait at least 3 minutes and re-
peat as above.
5) If set to hot water + central heating ‘II’, check that the
flow isolating valve (fig. 2 J) is fully open (turn anti-
clockwise).
To turnofftheboiler
Set the selector switch to the centre position off ‘0’. Turn
off the gas by turning the lever (fig. 2 G) on the gas servi-
ce tap to the right. Turn off the electricity supply.
To turn off the boiler leaving the pilot alight
Set the selector switch (fig. 1 A) to hot water only position
‘I’
turn off domestic water tap (fig. 2 H) under the appliance
and leave electricity supply on.
Frost precautions
Providing the boiler is not isolated from the electricity sup-
ply it has automatic protection from damage bv frost.
Overheating
If the pilot light or gas flame should go out whilst the boi-
ler is set to operate :
- Wait 3 minutes before relighting.
If the boiler goes out again this may be due to the over-
heat safety device operating.
- If this persists contact your service engineer.
Cleaning
The surface of the boiler may be cleaned using soap,
water and a soft cloth or a non-abrasive cleaner.
Service
To ensure that the appliance continues to work efficiently
and has a long life, it is important that it is serviced annually.
Ask your installer or local Gas Region for details of a
regular service scheme.
This appliance is suitable for use with most showers and
automatic washing machines.
Gas safety
(INSTALLATION AND USE)
REGULATIONS 1984
In your own interest and that of safety, it is the law that
all gas appliances are installed by competent persons in
accordance with the Gas Safety Installation and Use Regu-
lations 1984. If the appliance is installed in a compartment,
do not obstruct any purpose provided ventilation openings,
and do not use for storage purposes.
‘Gas leaks or faults’
If a gas leak or fau!t is suspected, turn off the appliance
and consult your local Gas Region or Service Engineer.
Clearances around your combination boiler
These minimum clearances must be maintained for opera-
tion and servicing.
Top above Air Inlet Duct
50
mm (2 in)
Bottom Below Case
200
mm (8 in)
Sides
100 mm (4 in)
Front
600
mm (24 in)
‘Warning’
If the pilot is extinguished for any reason wait at least 3
minutes before attempting to relight.
Electrical connections
The electrical supply connection must be made to a 240 V
50 Hz supply. The appliance must be protected by a 3 A
fuse. If a plug (BS 1363) is used or anv other type a 3 A
fuse must be fitted in the circuit.
This appliance must be earthed
To connect a plug
As the colour coding of the wires in the mains feed of the
appliance may not correspond with the colour marking
identification of your plug, proceed as follows :
- The wire which is coloured green/yellow must be
connected to the terminal in the plug marked with the
letter
‘E’
or by the earth symbol & or coloured green
or green and yellow.
- The wire which is coloured blue must be connected to
the terminal which is marked with the letter ‘N’ or
coloured black.
- The wire which is coloured brown must be connected to
the terminal marked
‘L’
or coloured red.