7 TEST & UTILITIES
7 0 0 Function test - Cleaning
turn the encoder to select the operating
mode
t-- = funct. at Max heating
power
t
--
= funct. at Max DHW power
t
--
= funct. at Min power
t-- activation can also be obtained by pressing the Reset
button for 10 seconds. The function is deactivated after
10 minutes or by pressing Reset
7 0 1 Bleed cycle press Menu
8 PARAMETER FOR TECHNICAL ASSISTANCE
8 1 Entering access code 222
turn the encoder clockwise to select 234 and press the
MENU/OK button
8 2 BOILER
8 2 0 NOT PRESENT
8 2 1 Fan status ON or OFF
8 2 2 Fan speed (x100) rpm
8 2 3 Circulation pump speed OFF - LS - HS
8 2 4 Distribution valve position Domestic hot water - Heating
8 2 5 Water ow rate (l/min)
8 2 6 NOT PRESENT
8 3 BOILER TEMPERATURE
8 3 0 Heating adjustment temperature (°C)
8 3 1 Heating ow temperature (in °C)
8 3 2 Heating backow temperature (in °C)
8 3 3 Domestic hot water temperature (in °C)
8 4 SOLAR APPLIANCE AND TANK
8 4 0 Accumulated measured temperature
activated only with the solar kit connected or external
tank
8 4 1 Solar collector temperature
8 4 2 Solar appliance water input temperature
8 4 3 Solar appliance low tank sensor temperature
8 4 5 Total circulation pump operating time delay for solar appliance
8 4 6 Total solar collector overheating time delay
8 5 SERVICE - TECHNICAL ASSISTANCE
8 5 0
Time remaining before next service
setting
from0 to 60 (months) 24 once the parameter is set, the boiler will show the user
the interval before the next service
8 5 1
Service warning authorisation 0 = OFF
1 = ON
OFF once the service has been performed, set the parameter
to clear the warning
8 5 2
Clearing the service warning Reset?
OK = yes
ESC = no
8 5 3 NOT PRESENT
8 5 4 PCB hardware version
8 5 5 PCB software version
8 5 6 PUS peripheral device interface software version

Table of Contents

Other manuals for CHAFFOTEAUX NIAGARA C 25 CF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CHAFFOTEAUX NIAGARA C 25 CF and is the answer not in the manual?

CHAFFOTEAUX NIAGARA C 25 CF Specifications

General IconGeneral
BrandCHAFFOTEAUX
ModelNIAGARA C 25 CF
CategoryBoiler
LanguageEnglish

Related product manuals