Inverter heat pump solution
PAGE \*
MERGEFORMAT 18
1) The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation
must be solid and fastened; the bracket must be strong enough and antirust treated;
2) Please don’t stack substances that will block air flow near inlet or outlet area, and there is no barrier
within 50cm behind the main machine, or the efficiency of the heat pump will be reduced or even
stopped;
3) The machine needs an appended pump (Supplied by the user). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m;
4) When the machine is running, there will be condensation water discharged from the bottom, please
pay attention to it. Please hold the drainage nozzle (accessory) into the hole and clip it well, and then
connect a pipe to drain the condensation water out.
b. The inlet and outlet water unions can’t stand the weight of soft pipes. The heat pump must be
connected with hard pipes!
DO NOT install water pipes in a way that they pass behind the heat pump's evaporator. In case this
cannot be avoided, cover the pipes with thermal insulation foam.