5.1 ELECTRICAL CONNECTION
• The Manufactuer does not provide the power cord or plug. All the needed cables and connection
parts must be supplied by the customer. All power cords must match the national electrical safety
regulations.
• Use 4 core cable (3Ph+Pe) of an adequate cross-section and connect to a thermal magnetic switch
protected by a 30mA Residual Current Device (RCD).
• The connection to the main power must be carried out by an authorized local electrician (mandatory).
• The electrician responsible of the connection must verify that the power plant conditions match the
national electrical safety regulations and are suitable for the machine requirements.
• The machine is built for fixed main connection only. The power cords must enter the electrical
cabinet from the top.
5. ELECTRICAL REQUIRMENT
ELECTRICAL DATA ACE 950 - 1390066
3P + PE
208 ± 1 0%
50 Hz
1 4 kW
Phases
Voltage [V]
Frequency [Hz]
Max Consumption [kW]
42 A
Current [A]
DUAL 1200 - 1390052
3P + PE
208 ± 1 0%
50 Hz
1 9 kW
50 A