Digital Power Meter 66200 Series User’s Manual
The test result of power measurement for 66202 Power Meter:
66202 Range Voltage: 500V Range Current: 20A Range
Fluke 5500 Output Parameter Max. Spec. Measured Result Min. Spec.
W 5035.12 4964.88
500Vrms
10Arms
60Hz
PF = 1
PF 1.000 0.9938
66202 Range Voltage: 150V Range Current: 0.2A Range
Fluke 5500 Output Parameter Max. Spec. Measured Result Min. Spec.
W 30.156 29.844
150Vrms
0.2Arms
400Hz
PF = 1
PF 1.000 0.9938