Chromalox
®
DIVISION
4
SECTION
ARC
SALES
REFERENCE
DATE
SERVICE REFERENCE
Installation Instructions
and
RENEWAL PARTS IDENTIFICATION
PK411-8
161-562790-001
JULY, 2006
(Supersedes PK411-7)
© 2010 Chromalox, Inc.
Type ARC Thermal Cutout
Sensing Bulb
with 7’
Standard Capillary
Temperature Maximum
Range
Style
Dia. Length
A.C. Rating
Model
(˚F)
(In.) ±1/2”
(Amps)
ARC-215 60-250˚ 5 3/8 4
ARC-219 60-250˚ 9 3/16 16-1/8
ARC-515 200-550˚ 5 3/8 3-1/4
ARC-519 200-550˚ 9 3/16 11-1/4
ARC-715 300-700˚ 5 3/8 3-11/16
ARC-715D* 300-700˚ 5 3/8 3-11/16
30 Amp
120-277 Vac
Resistive Loads
Single Phase
250 VA
120-277 Vac
(Pilot Duty)
Specifications — Table A
Figure 1
* This model has 15’ capillary
4-3/32
Length
Dia.
Bulb
(See Specifications — Table A)
2-21/32
2” O.D.
Typ.Capillary
2-21/32
3-1/8
3-3/8
5-7/8
Flow Factor~ 216-765-4231