Operating Instruction of ZHRV2-54T Digital Household Self-resetting Overvoltage and Undervoltage Protector
-1-
Built-in high-performance microcontroller, with high
reliability and strong antijamming capability.
LED Nixie tube displaying the operating voltage value.
Featuring with overvoltage and undervoltage protective function.
User can set the protection parameters by using the buttons.
Voltage measuring accuracy≤1%.
Measuring frequency: 45Hz-65Hz.
It can be installed on standard rail 35mm.
Functions and features
Model and meaning
Main technical parameters
Rated supply voltage
AC100V400V
AC220V
Rated supply frequency
Overvoltage actuation time
Undervoltage
actuation time
50/60Hz
0.1s
120200V,1s
120V,0.1s
5V
Voltage measuring error
≤1% (entire setting range)
Delay error
±10%+0.1s
Measuring accuracy
1%, true virtual value measurement
Rated insulation voltage
415V
Permissible relative humidity
≤50% (40) (without condensation)
Storage temperature
-25℃~55
Model and maximum
NT00-6A
Pollution level
Protection class
3
IP20
Electrical life
10
5
Mechanical life
6
10
Altitude
2000m
Operating ambient
-5℃~40
Panel schematic diagram
Setting of overvoltage operating value
Example
Rated operational voltage
Voltage lagged value
Setting of overvoltage operating value/digit+ button
ZH
Rated operational current: 50A, 63A,80A
Protection model
RV2 54T
Enterprise code
Voltage protection
Current specification
50A 63A 80A
50A
10kW
63A 80A
13kW 17kW
Rated operating frequency
Maximum operating current
(within 10min)
Maximum cross-section
of conductor
16mm
2
Operating instructions of button menu
Confirm modification button
Setting of Undervoltage operating value/digit- button
Button explanation
Long press for 3s
Confirm modification
The relay will automatically quit the menu and not save the modified
data if not operating the button for continuous 60s during setting
parameters.
It can change the setting value by pressing
The rightmost indication point flickers after entering overvoltage setting interface.
Flickers
Long press
Long press
Setting of Undervoltage operating value
Long press for 3s
16mm 16mm
2 2
Technical parameters
Setting range
Stepping amount Factory set value
Overvoltage operating value
210V280V
120V200V
5s600s
1V
1V
5s
250V
170V
15s
Breakover delay time
Breakover delay display
Operating voltage value of LED Nixie tube flickers during breakover
delay; operating voltage value of LED Nixie tube will be normally on
after delay is over and output relay is with breakover.
LED Nixie tube
Flickers
Confirm modification
The
relay
will
automatically quit the menu and not save the modified
data if not operating the button for continuous 60s
during
setting
parameters.
It can
change the setting value by pressing
The rightmost indication point flickers after entering Undervoltage
setting interface.
of short circuit protector
rating
temperature
Undervoltage operating value
for 3s to enter setting interface of Undervoltage operating value:
for 3s to enter setting interface of Undervoltage operating value:
R
Conform to:IEC609 4 7 - 5 - 1 standard
Question and Answer IconNeed help?

Do you have a question about the Chtce ZHRV2-54T and is the answer not in the manual?

Overview

This document describes the ZHRV2-54T Digital Household Self-resetting Overvoltage and Undervoltage Protector, a device designed to safeguard electrical systems from voltage fluctuations. It conforms to the IEC60947-5-1 standard.

Function Description

The ZHRV2-54T protector is built around a high-performance microcontroller, ensuring high reliability and strong anti-jamming capabilities. Its primary function is to provide overvoltage and undervoltage protection for household electrical systems. The device continuously monitors the operating voltage and, upon detecting a voltage outside the user-defined safe range, initiates a protective action.

A key feature is its self-resetting capability. Once the voltage returns to the normal operating range after a protective trip, the device will automatically restore power after a set delay, eliminating the need for manual intervention. This ensures continuous operation and minimizes downtime.

The protector features an LED Nixie tube display that shows the real-time operating voltage value. This allows users to easily monitor the system's voltage status. Users can also set various protection parameters, such as overvoltage and undervoltage operating values, and breakover delay time, directly on the device using intuitive buttons.

The device incorporates a breakover delay function, which prevents immediate tripping due to transient voltage spikes. During this delay, the LED Nixie tube flickers, indicating that the device is in a protective delay state. Once the delay is over and the voltage is within the safe range, the output relay will close, and the LED Nixie tube will display the operating voltage normally.

Important Technical Specifications

Electrical Characteristics:

  • Rated Supply Voltage: AC220V
  • Rated Operational Voltage: AC100V~400V
  • Rated Supply Frequency: 50/60Hz
  • Rated Operational Current: Available in 50A, 63A, and 80A models.
  • Maximum Operating Current (within 10min): Matches the rated operational current (50A, 63A, 80A).
  • Rated Operating Frequency: 10kW, 13kW, 17kW (corresponding to 50A, 63A, 80A models respectively).
  • Rated Insulation Voltage: 415V
  • Voltage Measuring Error: ≤1% (across the entire setting range).
  • Delay Error: ±10%+0.1s
  • Measuring Accuracy: 1%, true virtual value measurement.

Protection Parameters (Settable by User):

  • Overvoltage Operating Value: Settable from 210V to 280V, with 1V stepping. Factory set to 250V.
  • Undervoltage Operating Value: Settable from 120V to 200V, with 1V stepping. Factory set to 170V.
  • Overvoltage Actuation Time: 0.1s
  • Undervoltage Actuation Time: 120~200V for 1s, or <120V for <0.1s.
  • Voltage Lagged Value: 5V
  • Breakover Delay Time: Settable from 5s to 600s, with 5s stepping. Factory set to 15s.

Environmental and Mechanical Specifications:

  • Protection Class: IP20
  • Pollution Level: 3
  • Electrical Life: 10^5 operations
  • Mechanical Life: 10^6 operations
  • Altitude: <2000m
  • Operating Ambient Temperature: -5°C to 40°C
  • Permissible Relative Humidity: ≤50% (at 40°C, without condensation)
  • Storage Temperature: -25°C to 55°C
  • Maximum Cross-section of Conductor: 16mm² (for all current specifications).
  • Installation: Designed for installation on a standard 35mm DIN rail.
  • Dimensions: Approximately 60mm (width) x 77mm (height) x 65.5mm (depth).

Usage Features

The ZHRV2-54T is designed for ease of use and configuration.

  • Display: The LED Nixie tube provides clear, real-time feedback on the operating voltage. During breakover delay, the display flickers, indicating a temporary protective state.
  • Parameter Setting:
    • Overvoltage Setting: Long press the "up arrow" button for 3 seconds to enter the overvoltage setting interface. The rightmost indication point will flicker. Use the "up arrow" and "down arrow" buttons to adjust the value, and the "i" button to confirm.
    • Undervoltage Setting: Long press the "down arrow" button for 3 seconds to enter the undervoltage setting interface. The rightmost indication point will flicker. Use the "up arrow" and "down arrow" buttons to adjust the value, and the "i" button to confirm.
    • Breakover Delay Time Setting: Long press both the "up arrow" and "down arrow" buttons for 3 seconds to enter the breakover delay time setting interface. The rightmost indication point will flicker. Use the "up arrow" and "down arrow" buttons to adjust the value, and the "i" button to confirm.
  • Voltage Calibration: Before energizing the relay, long press both the "up arrow" and "down arrow" buttons for 3 seconds to enter the voltage value calibration interface. All three indication points will flicker. This allows for fine-tuning the voltage measurement if needed.
  • Automatic Exit from Menu: If no button is operated for 60 seconds during parameter setting, the relay will automatically exit the menu without saving any unsaved modifications.
  • Automatic Reset: After a voltage fault, once the voltage returns to the normal range and the breakover delay time elapses, the device will automatically reset and restore power.
  • Wiring: The device supports a clear wiring diagram for null line, fire wire, and connected load. It is recommended that the rated operating current of the circuit breaker used with this device be 75% of the maximum current of the voltage relay (Ie = 0.75Imax).

Maintenance Features

The ZHRV2-54T is designed for robust operation with minimal maintenance, but adherence to installation and usage guidelines is crucial for its longevity and performance.

  • Warranty: The product comes with an 18-month warranty under regular service conditions.
  • Professional Installation: Installation, operation, and overhaul of this product must be carried out by a qualified professional.
  • No Disassembly: Users are strictly prohibited from disassembling or maintaining the product, regardless of its condition. Unauthorized tampering will void the warranty and absolve the manufacturer of liability for any accidents.
  • Wiring Precautions:
    • Always refer to the provided wiring diagram.
    • The power incoming line must not be wired in the same tube with other strong current electric wires to avoid interference. Shielded wire should be used if necessary.
  • Environmental Considerations:
    • Avoid using the product in dusty places, areas with corrosive gas, direct sunlight, or rain.
    • Do not use the product in mediums with explosion hazards, or mediums that contain corroding metal, gas destroying insulation, or conducting dust.
    • Store and use the product under its rated supply voltage, stipulated temperature, altitude, and humidity.
  • Safety Warnings (Danger Warning):
    • Always operate with the power off during installation and wiring.
    • Confirm that the supply voltage matches the rated supply voltage of the product before energizing.
    • Failure to observe these warnings can lead to electric shock or fire.

For further information, users can contact CHTCE Technology Co., Ltd. via the provided telephone numbers or visit their websites.

Chtce ZHRV2-54T Specifications

General IconGeneral
BrandChtce
ModelZHRV2-54T
CategorySurge Protector