Questions and Answers

  • D
    Don SmithAug 5, 2025
    Why does the CIBIN Refrigerator compressor stop due to thermal cut-out?
    • Z
      zroyAug 5, 2025
      If the CIBIN Refrigerator compressor stops due to thermal cut-out switch intervention, several factors could be responsible: * The condenser might be inefficient. Try cleaning the fins and straightening any bent fins using a comb. * There might be insufficient airflow to the condenser. Inspect the fans to ensure they are working correctly, rotating in the right direction, and in good condition. * Air recirculation on the condenser could be occurring. Relocate the refrigerator to a more suitable spot. * The motor winding may have short-circuited or earthed, requiring a compressor replacement.
  • C
    Claudia YoungAug 9, 2025
    How to fix insufficient cooling capacity in CIBIN Refrigerator?
    • A
      Alan HoodAug 9, 2025
      If your CIBIN Refrigerator isn't cooling enough, and the machine can't reach the set temperature, here's what might be happening: 1. Ice buildup on the evaporator: Perform a manual defrost cycle to remove the ice. 2. Incorrect parameter settings: Restore the parameters to their correct values as indicated in the relevant table. 3. Frequent door openings: Reduce how often you open the refrigerator door. 4. High ambient temperature: Improve ventilation in the room where the refrigerator is located. 5. Dirty condenser: Clean the condenser fins, straightening them with a comb if needed. 6. Defrost solenoid valve coil issue: Replace the coil. 7. Faulty defrost control relay switch: Replace the electronic regulator.
  • C
    Charles WalkerAug 14, 2025
    What to do if CIBIN Refrigerator compressor buzzes but won't start?
    • S
      Stephanie VillaAug 14, 2025
      If your CIBIN Refrigerator compressor won't start but makes an intermittent buzzing sound, consider these potential causes: * The line voltage might be too low. Measure the input voltage and, if it's below the tolerance limits, contact your power supplier. * The electrical connections may be incorrect due to tampering. Restore the wiring to its original configuration using the electrical diagrams. * The electrical motor winding could be defective. Check the winding circuit for continuity and replace the compressor if necessary.
  • T
    Terry TurnerAug 20, 2025
    Why won't my CIBIN Refrigerator compressor start with no buzzing?
    • H
      Hannah CarlsonAug 20, 2025
      If your CIBIN Refrigerator's compressor isn't starting, and there's no buzzing sound, even though it's powered and the temperature setting is lower than the cold room's temperature, the following could be the cause: * The power supply to the compressor might be cut off. Disconnect the line and check its circuit continuity. * The electrical motor winding could be cut off. Check the winding circuit's continuity and replace the compressor if needed. * The electronic regulator relay switch might be faulty. Replace the electronic regulator.
  • S
    Samantha MooreAug 25, 2025
    Why won't my CIBIN Refrigerator start even though the display is on?
    • T
      Travis GordonAug 26, 2025
      If the display of your CIBIN Refrigerator is lit and the regulator is on, but the machine won't start, it could be because the set point is set too high. Check the set point and lower it if needed.
  • C
    Craig SinghAug 30, 2025
    Why are the lights and door resistor not working on my CIBIN Refrigerator?
    • T
      Theresa StevensonAug 30, 2025
      If the auxiliary circuits (cold room lighting and door resistor) in your CIBIN Refrigerator aren't working, the fuse may be faulty. Replace the fuse.

Summary

Unit Dimensions

Cold Room Electrical Connection

Technical Data & Specifications

Cold Room Perforation Guide

Troubleshooting Guide

Electrical Diagrams

Thermodynamic Diagrams

Spare Parts List

Electronic Controller Parameters

Level 1 Parameters Table

Table of primary electronic controller settings and their values.

Level 2 Parameters Table

Table of secondary electronic controller settings and their values.

CIBIN KUMA 04123N Specifications

General IconGeneral
BrandCIBIN
ModelKUMA 04123N
CategoryRefrigerator
LanguageEnglish

Related product manuals