If the engine floods, please proceed as it follows:
Unscrew and remove spark plug (Picture 1 pos. 3), wipe and dry it.
Verify that the choke lever B is in horizontal position as shown in the Picture 14.
Pull the starting handle (Picture 1 pos.4) at least 20 times.
Mount the spark-plug; accelerate to the maximum using the steady throttle lever
(Picture 10 pos.4).
Start the engine.
In case the engine doesn’t start, please act as follows:
Unscrew and remove spark plug, wipe and dry it.
Turn the engine upside-down in order to have the hole of the spark-plug
downwards.
Pull the starting handle (Picture 1 pos.4) at least 20 times and check if the fuel
pours out the spark-plug hole.
Dry the outside around the centre spark plug.
Assemble the spark plug and repeat starting procedure keeping the gas lever
at maximum position and the choke lever B in horizontal position ( Picture 14).
Picture 16 - Position of the spark plug
WARNING
Don’t waste the fuel in the environment. If possible, collect it in a suitable
container.
When the spark-plug is connected to the cap, it emits high-voltage
current, which can be dangerous especially for people with pacemakers
or heart diseases.
Several pulls for starting the engine are very tiring. So please rest