LCD display 128 x 64 pixels
Power supply Battery Mignon LR6
(2 pieces),
Battery change display
Housing ABS plastic
Storage temperature -25°C to +50°C
Application temperature -10°C to +50°C
Relative air humidity 0 to 90%, non-condensing
Wood moisture 6-30 % by weight
Material and construction
material
0-100 digits
Accuracy +/- 1%
6. Table of Wood Types
1 2 3 4 5 6
6 8,0 6,5 6,7 9,6 7,2
8 10,4 7,5 9,1 10,9 9,7
10 11,4 8,7 10,5 12,4 11,8
11 12,5 9,6 11,3 13,4 12,7
12 13,6 10,5 12,2 14,3 13,6
13 14,5 11,2 12,9 15,1 14,5
14 15,5 11,8 13,5 16,0 15,4
15 16,6 12,5 14,1 17,0 16,2
16 17,7 13,1 14,8 17,8 17,0
17 18,9 14,0 15,6 18,5 17,8
18 19,7 14,8 16,3 19,2 18,5
19 21,0 15,7 17,0 20,1 19,2
20 22,5 16,6 17,7 21,3 20,0
21 23,4 17,3 18,5 22,4 20,8
22 24,6 18,0 19,3 23,6 21,6
23 26,3 19,0 20,1 24,9 22,8
24 27,2 19,7 20,8 25,9 23,6
25 27,9 20,5 21,4 26,6 24,4
26 28,5 21,4 22,8 27,3 25,3
28 - 23,0 24,1 28,5 27,5
30 - 23,8 24,8 29,1 28,4
4. Battery Display
If the battery display is empty, the batteries must be replaced.
However, it is still possible to perform measurements for a
short time.
4.1 Insert batteries
The battery compartment is located on the rear of the HPM
3000B measuring device. Two batteries of size AA Mignon
LR6 are required for operation.
The cover is opened by pressing gently on the battery
compartment cover and sliding at the same time. The batteries
must now be inserted making sure the polarity is correct,
and the cover closed again.
5. Technical Data